Item5: System controller block diagnosis
System controller block diagnosis analyzes the following contents.
ID
Diagnosis description
0x01
IIC communication test (clock IC)
0x02
IIC communication test (EEPROM)
0x03
IIC communication test (power supply microcomputer)
0x04
IIC communication test (sub-microcomputer of the inside panel)
0x05
IIC communication test (sub-microcomputer of the handle)
0x06
IIC communication test (sub-microcomputer of the rear panel)
0x09
IIC communication test (I/O expander)
0x10
Version matching test (power supply microcomputer)
0x11
Version matching test (sub-microcomputer of the inside panel)
0x12
Version matching test (sub-microcomputer of the handle)
0x13
Version matching test (sub-microcomputer of the rear panel)
When an error is detected in the IIC communication test, it indicates a possible failure in the communication line or device.
*: When an error is detected in the version matching test, upgrade again to a compatible version.
Contact your local Sony Sales Offi ce/Service Center for information on versions.
Item6: Power block diagnosis
Power block diagnosis analyzes the following contents.
ID
Diagnosis description
0x01
Power switch readout
0x02
Battery recognition
0x03
Power supply state
Item7: Diagnosis between image processor and display blocks
Diagnosis between Image processor and Display blocks analyzes the following contents.
ID
Diagnosis description
0x80
Video signal line test
When an error is detected, it indicates a possible failure in the chip or the signal line between chips.
3-8 (E)
Error value
-1: Cannot readout power
switch
-4: Cannot diagnose since
the power switch is not
set to CAMERA
-1: Cannot communicate with
battery
-4: Cannot diagnose since
the battery is not connected
-1: Power supply is not
controlled correctly
-4: Cannot diagnose since
the power switch is not
CAMERA
Error value
Type 1/2
-1: Test pattern checking
1, 2
failure
Error value
Type 1/2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
-1: Error
1, 2
Type 1/2
Note
1, 2
Power switch must be set to
CAMERA
1, 2
Appropriate battery must be
connected
1, 2
Power switch must be set to
CAMERA
Note
Conducts a test from camera
signal processor IC to base band
processing IC. Monitor output
images will be distorted during
the test.
Note
_
_
_
_
_