GE Homespring Operation Manual page 8

Water purifier system
Hide thumbs Also See for Homespring:
Table of Contents

Advertisement

System Parts List
UFC 211 and UF 211
System
(pre-assembled)
System Base
Carbon Prefilter
Two Stainless Steel Flex Hoses
Inside the bubble bag:
1 - Drain Solenoid Valve
(normally closed)
1 - Nylon Elbow
2 - 1/4" Mini Ball Valves
with Plugs
1 - Air Relief Valve
3 - 3/8" Bolts
Surface Water Kit (optional)
1 - External Prefilter
Housing
1 - Wall Bracket Kit
Mounting Screws
1 - Inlet Solenoid Valve
(normally open)
Preparing for Installation
Pre-Installation Inspection
Prior to beginning the installation, check for the following:
Space near point of entry of water supply
Footprint and height clearance
Footprint: minimum 18" x 18" (46 x 46 cm)
Height Clearance: minimum 74" (188 cm)
Indoors with ambient temperature between 40-90°F
(4-32°C)
Drillable floor, patio stone, or wood base. Patio stone
must be securely anchored to floor
Electrical outlet, uninterruptable 120VAC, within 6' (182.8
cm)
Existing water equipment (e.g. water softeners, filters
upstream and UV downstream)
Recommended household water pressure is 30 psi
minimum. If water pressure is less than 30 psi, adjust
backpulse tank pressure. Refer to Step 4 in the System
Installation section.
8
Transformer (120VAC)
Advanced Plus
Controller
Cap Wrench
2 - 3/4" Inlet/Outlet
fittings
1 - 1/2" Nipple
3 - 1/4" x 2-1/2"
Anchors
3 - Shims
1 - 1/4" Mini Ball Valve
with Plug
1 - Check Valve
4 - 1/2" Lag Bolts
1 - External Prefilter
Cartridge (20- micron
nominal)
Drain within 20' (610 cm) and up to 72" (183 cm) high. If
the system is to be equipped with an inlet solenoid valve,
the drain cannot be higher than the drain port of the
system for proper draining.
NOTE: All outlets downstream of the system will provide
filtered water. A dedicated line, diverted from the main water
line, is recommended to be installed upstream of the system for
all exterior taps, pool or hot tub makeup valves, and irrigation
systems. This set-up will help prolong the life of the system
membrane.
Part Identification
Air Relief Valve
Internal
Prefilter
Membrane
Module
Backpulse Tank
System Base
figure 4
System Installation
1
The system is shipped fully assembled, except for the
system base. Attach the system base to the backpulse tank,
using the supplied 3/8" bolts and washers.
figure 5
System Cap
Inlet port
System Casing
Drain port
Outlet port
Air Bladder
Valve

Advertisement

Table of Contents
loading

This manual is also suitable for:

Homespring ufc 211 seriesHomespring uf 211

Table of Contents