GE UFC 211 Owner's Manual

GE UFC 211 Owner's Manual

Water purifier system
Hide thumbs Also See for UFC 211:

Advertisement

Water Purifier
Water Purifier
Water Purifier
Water Purifier
Water Purifier
T T T T T able of Contents:
able of Contents:
able of Contents:
able of Contents:
able of Contents:
A. INTRODUCTION...................................Page 2
B. SAFETY WARNINGS................Pages 2 to 4
C. CERTIFICATION...................................Page 4
D. OPERATIONS.............................Pages 5 to 7
E. MAINTENANCE SCHEDULE....Pages 7 to 9
F. WINTERIZATION...................Pages 10 to 12
G. TROUBLESHOOTING..........Pages 13 to 14
I. SPECIFICATIONS.................Pages 19 to 20
J. FAQ............................................Pages 21 to 22
System
System
System
System
System
Owner's Manual
Retain these instructions for future reference.
IMPORTANT: See safety warnings inside
UFC 211
UFC 211
UFC 211
UFC 211
UFC 211
UFC 209
UFC 209
UFC 209
UFC 209
UFC 209
UF 211
UF 211
UF 211
UF 211
UF 211
UF 209
UF 209
UF 209
UF 209
UF 209
UFC 207
UFC 207
UFC 207
UFC 207
UFC 207
UF 207
UF 207
UF 207
UF 207
UF 207
01/2005 P/N 23262
1
2006 V10.0 P/N 23331

Advertisement

Table of Contents
loading

Summary of Contents for GE UFC 211

  • Page 1: Table Of Contents

    Contents: able of Contents: able of Contents: able of Contents: A. INTRODUCTION........Page 2 B. SAFETY WARNINGS....Pages 2 to 4 C. CERTIFICATION........Page 4 UFC 211 UFC 211 UFC 211 UFC 211 UFC 211 UFC 209 UFC 209 UFC 209...
  • Page 2: Introduction

    Installation Date Manufacturer’s Contact Information B. SAFETY WARNINGS GE Water & Process Technologies 3239 Dundas Street West It is important to read and understand the following safety Oakville, ON, Canada warnings to ensure reliable service from your System.
  • Page 3 WARNING! WARNING! Biological Operational The System is not intended for the treatment of water All System Parts and Components must be installed from an obvious contamination source (such as in accordance with all local building and plumbing sewage or wastewater). codes.
  • Page 4: Certification

    USEPA’s Guide Standard and Protocol for Testing Microbiological Water Purifiers (OPP Task Force Report, 1987) as interpreted by the WQA and to NSF/ANSI 42 and 53. The UFC 100, UFC 207, UFC 209, and UFC 211 models (All equipped with a Carbon Prefilter) have been certified as:...
  • Page 5: Operations

    D. OPERATIONS Normal Operation System Description The System does not require any special attention under normal operation conditions. The System uses existing water pressure in the water supply line to filter water and Air Relief will continue to operate even during a power failure. Valve System Electricity is only required to activate the self-cleaning...
  • Page 6 Setting Flush/Drain Time 2 2 2 2 2 FIGURE 4 FIGURE 3 Press NEXT four times until “PROGRAM” flashes on screen. Press NEXT three times until “START TIME” Press ENTER. flashes on screen. Press ENTER. Press the UP and DOWN arrows to set the Press the UP and DOWN arrows to set the hour.
  • Page 7: Maintenance Schedule

    A Homespring™ Authorized Technician must perform all Controller Functions service and maintenance. As part of the annual A. Manual Flush maintenance, the Homespring™ Authorized Technician Note: For use when the instructions in this manual call for will perform an Integrity Test to check the condition of the a Manual Flush.
  • Page 8 System Membrane Cleaning The following System cleaning procedures are performed by the Homespring ™ Authorized Technician during the annual maintenance. WARNING! FIGURE 7 Disposable protective gloves must be worn during maintenance of the System to protect your hands. Once the cap is removed, wipe the System Cap out with At the end of the procedure, wash your hands a clean, soft cloth, remove the O-ring carefully, wipe the thoroughly with soap and water.
  • Page 9 Horizontally-mounted Systems: With the Internal Prefilter still removed, unscrew the ” WARNING! ½ Brass Plug on the Air Vent Assembly near the System Cap. Be careful to avoid MC1 cleaning agent coming in contact with skin or clothing. Wash the mixing container well before reuse.
  • Page 10 F. WINTERIZATION PROCEDURE 2 2 2 2 2 Remove the drain hose and Nylon Elbow from the Tools/Supplies Required Drain Solenoid Valve and install a ½” MNPT or ¾” MNPT PVC plug (depending on the size of the port) into the For all Systems you will need: Drain Solenoid Valve.
  • Page 11: Winterization

    C) propylene glycol based plumbing antifreeze. The same as the initial set-up. UFC 207, UF 207, UFC 209, UF 209, UFC 211 and UF 211 Series models do not have enough internal space to accommodate 3 gallons of antifreeze initially. Remove the...
  • Page 12 5 5 5 5 5 9 9 9 9 9 Open the Outlet Valve and a nearby COLD water Close the Inlet Valve and Outlet Valve. Partially tap to remove chlorine from the System. Run the tap fully drain the System using the Manual Flush function for 1 open for 5 minutes.
  • Page 13: Troubleshooting

    G. TROUBLESHOOTING If there are any problems with the Homespring™ Water Purifier System, contact your dealer or HomespringCustomer Service immediately. Area Problem / Situation Corrective Action / Remedy A part is missing Contact your Dealer. System leaks water Tighten System Cap. Check O-ring is in place, is clean and is intact.
  • Page 14 Area Problem / Situation Corrective Action / Remedy Water does not flow through Pres s RED button on top of housing to releas e air until water flows from button as air m ay be trapped in hous ing. Replace External Prefilter cartridge if water press ure has External Prefilter been gradually decreas ing as the External Prefilter m ay (with Surface Water...
  • Page 15: Replacement Part List And Procedures

    H. REPLACEMENT PART LIST AND Using the Cap Wrench, remove the System Cap. PROCEDURES Put on a pair of disposable gloves and carefully remove and dispose of the Internal Prefilter. Replacement Procedures Check that the Thimble Filter is in place, seated in A.
  • Page 16 UFC 207, UF 207, UFC 209, UF 209, UFC 211 and UF 211 Series 22 23 FIGURE 20...
  • Page 17 UFC 207, UF 207, UFC 209, UF 209, UFC 211 and UF 211 Series Ite m No. Pa rt Numbe r De scription Syste m 23106 Carbon Prefilter, 12" UFC models only 23155 Carbon Prefilter, 6" 23107 Stainless Steel Prefilter, 12"...
  • Page 18 Surface Water Option Kit Part Item No. Number Description Surface Water Option Kit / External Prefilter Kit Parts External Prefilter Replacement 23071 Cartridge 23090 External Prefilter O-Ring 23061 1" to ¾" Reducing Bushing 23317 Inlet Solenoid Valve 23054 Check Valve 23137 ¾...
  • Page 19: Specifications

    I. SPECIFICATIONS P a r a m e te r U F C 2 07 / U F 2 07 U F C 2 0 9/ U F 2 0 9 U F C 21 1 / U F 21 1 R e c o m m e n de d m a x im u m p e ak 6 g p m (2 2 .7 L p m ) 9 gp m (34 L p m )
  • Page 20 Controller Specifications Controller Advanced Plus Fuse 3.0 Amp Voltage in 24VAC Voltage output 24VAC Number of outputs Program 1 2 flush/backpulse cycles Estimated water use¹ 7.5 gal. (28.4 litres) (US gallons) Program 2 4 flush/backpulse cycles Estimated water use 15 gal. (56.7 litres) (US gallons) Program 3 2 flush/backpulse cycles,...
  • Page 21 Flushing: Flushing includes a Front-flush and a Back- J. FREQUENTLY ASKED flush. Systems that are installed in municipal, cistern, or QUESTIONS (FAQ) ground water sources may use the flushing method to control the fouling rate of the membrane. What does the System do? This System has been tested to significantly physically (5).
  • Page 22 What minimum water line pressure is recommended Will the System act as a water softener? for the System? The system will not soften water or remove dissolved The minimum water pressure requirement is 30 psi. If solids. Given the pore size of the membrane, dissolved the System is installed on a pump/pressure tank particles smaller than 0.02 microns nominal will pass scenario the requirement may be less.

This manual is also suitable for:

Uf 209Uf 207Homespring uf 211

Table of Contents