GE Homespring Operation Manual page 7

Water purifier system
Hide thumbs Also See for Homespring:
Table of Contents

Advertisement

System Configuration for Optional Surface
Water Option Kit
Systems purchased with the surface water option kit are
installed at the same location and in the same manner as a
standard system, with the exception of additional parts, which
must be installed, as shown. Additional parts include an inlet
solenoid valve, check valve, and external prefilter.
1. Inlet Valve
2. Bypass Valve
3. Outlet Valve
4. Drain Solenoid Valve
5. Drain Hose
6. Advanced Plus Controller
7. Inlet Solenoid Valve
8. Check Valve
9. External Prefilter
figure 3
NOTE: The inlet solenoid valve of the surface water option kit
creates a non-pressurized draining of the system. The entire
drain line, including the floor drain, must be below the drain
port of the system.
WARNING:
water sources, an external prefilter of 20-microns
(e.g. Pentek S1-20BB) nominal micron size is required.
Failure to provide this level of prefiltration may lead to
system damage and will void the warranty. A damaged
system may cause serious personal injury, illness, and/
or death.
Tools, Supplies and Parts
WARNING:
system should be maintained in sterile condition so that
the risk of cross-contamination is minimized. Bacteria,
parasites, and viruses can live for long periods of
time. As a result, dangerous organisms can be carried
from one installation or maintenance site to another
and may potentially cause serious personal injury,
sickness and/or death. Proper tool care and disinfection
procedures will minimize these risks.
24 VDC
When treating surface
Tools used to install the
The following list of tools and supplies are required for the
completion of this installation:
Tools (not provided)
Slip Joint Pliers 12"
Pipe Wrench 12"
Adjustable Wrenches
Torpedo Level
Fine Slot Drivers
Phillips Drivers: #0, 1
Nut Drivers: 5/16, 3/8
Supplies Required (not provided)
Copper Pipe
Ground Wire
Flux and Flux Brush
Solder (lead free)
Assorted Copper
fittings
Plumber Tape or Pipe
Dope (for potable
water) NSF Approved
3 Water Shut-off Valves
(same size as install
piping)
Unscented Chlorine
Bleach (Clorox) - 5-6%
or 12%
Tools Supplied with Integrity Test Kit
Integrity Tester
Cap Wrench
Silicone Lubricant -
DOW CORNINg 111
Two 1/4" Tubings
Spare Parts (recommended)
AA Batteries
Inlet Solenoid Valve
Air Relief Valve
Stainless Steel Flex
Hose
3/4" Inlet/Outlet Fitting
WARNING:
recommended for use as the bypass, inlet and outlet
valves. Gate valves have a tendency to leak, allowing
unfiltered water to mix with filtered water. The result
may cause personal injury, sickness and/or death.
Knife
Air Pump
1/4" Hex Key
Torch with Gas
Snips
Robertson Drivers: #1, 2
Masonry Drill with 3/8"
Bit
Pen or Pencil
Funnel
Hose Clamps
Suspension Strap
Tie Wraps or Cable Ties
5/8" Hose for Drain
(comply with local
plumbing code)
2' x 2' Patio Stones
(required only for
heated floor)
Housing Wrench
Two Pressure Gauges
Digital Air Pressure
gauge
O-ring
Drain Solenoid Valve
Advanced Plus
Controller
1/4" Mini Ball Valve
with Plug
1/2" Nipple
Ball valves are
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Homespring ufc 211 seriesHomespring uf 211

Table of Contents