GE Homespring Operation Manual

GE Homespring Operation Manual

Water purifier system
Hide thumbs Also See for Homespring:

Advertisement

Homespring
by GE
TM
Water Purifier System
Operations Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for GE Homespring

  • Page 1 Homespring by GE Water Purifier System Operations Manual...
  • Page 2: Table Of Contents

    ANNUAl mAINTeNANCe ..........40 H. WINTeRIzATION PROCeDURe ........42 I. TROUBleSHOOTINg ............45 J. SPeCIfICATIONS ............... 47 K. fReQUeNTly ASKeD QUeSTIONS (fAQ)....48 l. RePlACemeNT PART lIST AND PROCeDUReS ..50 m. HOmeSPRINg WATeR PURIfIeR SySTem lImITeD WARRANTy ................56...
  • Page 3: Introduction

    By purchasing the Homespring Water Purifier System, you features of the Homespring Water Purifier System. It is not have taken the first step in providing safer, great tasting water intended to be a definitive dissertation on the principles set for your entire home.
  • Page 4: Safety Warnings

    32°F(0°C). Failure to do so may cause the Homespring Authorized Service Person. System to dry, freeze, become damaged, and will void Except in emergencies, do not open the Bypass Valve all warranties.
  • Page 5 Do not drink the Program (NELAP) Accredited #05234CA water if the System has been operated in bypass mode. The Homespring UF200 Series Water Purifiers have If the System has been operated in bypass mode and been tested by BioVir Laboratories Inc. and found if the water is being drawn from a well or surface to meet all the requirements of the USEPA’s Guide...
  • Page 6: Installation Instructions - Vertical

    All sales, commissioning and maintenance personnel are line. Usually this is near the water meter. For private pump/ required to participate in a Homespring Certified Technician pressure tank style systems, locate the outlet of the pressure training program to ensure that they have been trained to tank.
  • Page 7 System Configuration for Optional Surface The following list of tools and supplies are required for the completion of this installation: Water Option Kit Tools (not provided) Systems purchased with the surface water option kit are installed at the same location and in the same manner as a •...
  • Page 8 System Parts List • Drain within 20' (610 cm) and up to 72" (183 cm) high. If UFC 211 and UF 211 the system is to be equipped with an inlet solenoid valve, the drain cannot be higher than the drain port of the •...
  • Page 9 Failure to do so may result in damage to the system and will void all warranties. WARNING: Be sure to always verify and set backpulse tank pressure. The Homespring system must be empty when checking pressures.
  • Page 10 Pipe Assembly and Installation The two inlet/outlet fitting assemblies are shipped Ensure that all threaded connections are fitted with NSF pre-assembled, with the mini ball valves and plugs already approved plumber tape or pipe dope (for potable water) to installed. Ensure that the plumber tape at both threaded ends prevent leakage.
  • Page 11 the system to the floor with the supplied 1/4" x 2-1/2" anchors Applicable to Systems in Non-Surface Water (for concrete floor) or use screws (not supplied) for wood floors. Applications Only: NOTE: If the system is being installed on a heated floor, use a Connect the inlet and outlet fitting assemblies to the 3/4"...
  • Page 12 Installing the Controller 1 or 2): The floor drain and/or drain hose may be raised above the drain port of the system. The entire drain line must be leak- proof, The floor drain does not have to be in the same room as WARNING: the system.
  • Page 13 Setting the Controller Mount the controller using the keyhole located at the NOTE: Electrical power to the controller must be ON to back of the controller on the screw head. Level the controller. activate the flushing and draining sequences. The batteries Remove the controller front cover and drill two additional are for keeping the time in case of power failure and will not holes suitable for a #8 screw into these two holes and secure...
  • Page 14 Setting the Program Setting the Flush/Drain Interval: Choosing a program: Water Clarity Advanced Plus Controller Low Turbidity Program 1 less than 0.5 NTU Medium Turbidity Peaks to 1.0 NTU, less than 72 Program 2 min. per day High Turbidity figure 18 Peaks to 5.0 NTU, less than 72 Program 3 min.
  • Page 15 WARNING: For all surface water To manually flush the system, press NEXT once. “MANUAL” installations, the Homespring Certified Technician must flashes on the screen. Press MANUAL FLUSH to open the drain inform the homeowner and home occupants that the solenoid valve. If the MANUAL FLUSH button is held down for...
  • Page 16: Commissioning - Vertical

    D. commissioning - vertical Ensure that the O-ring is seated at the lip of the external prefilter housing. Screw the external prefilter housing into the external prefilter head. Tighten the connection with the housing wrench. WARNING: The system must be filled with water at all times once commissioned.
  • Page 17 Remove the system cap and remove the internal Using the controller, initiate a manual flush sequence. prefilter. Place the internal prefilter in a clean, dry area. Ensure Refer to the instructions in the Controller Functions section on that the thimble filter is seated properly. Replace the system how to perform a manual flush sequence.
  • Page 18 The integrity test is conducted at initial commissioning after the 15-minute flush and subsequent figure 25 sanitization and on an annual basis by a Homespring qualified technician. Close inlet and outlet valves. Use the controller to Test Description initiate a manual flush sequence to bring the system pressure to zero.
  • Page 19 If a pass is indicated then the system integrity is good and it is Inlet Mini possible to proceed to the next step. Ball Valve Integrity Test Fault Inlet 1/4” Valve tubing WARNING: When performing a Drain Membrane Integrity Test there can be several causes Solenoid for a false failure, such as leaks in fittings and/or tubing Valve...
  • Page 20 Ensure that the inlet valve is still in the closed position. Replace the system cap and open the inlet valve. Turn on Once a PASS green LED is achieved, close all mini ball valves a cold water tap to remove any remaining air and residual and remove both 1/4"...
  • Page 21: Installation Instructions - Horizontal

    The following documents are shipped with the system: All sales, commissioning and maintenance personnel are • Owner’s Manual • Service Tag required to participate in a Homespring Certified Technician • Congratulations Letter • Warranty Card training program to ensure that they have been trained to •...
  • Page 22 System Configuration for Standard Installations System Configuration for Optional Surface Water Option Kit For households on a municipal system, locate the water main, which connects the household to the municipal supply Systems purchased with the surface water option kit are line.
  • Page 23 System Parts List The following list of tools and supplies are required for the completion of this installation: UFC 211 and UF 211 Tools (not provided) • System • Transformer (120VAC) • Slip Joint Pliers 12" • Knife (pre-assembled) • Pipe Wrench 12"...
  • Page 24 Planning WARNING: The horizontal mounting bracket must be assembled and Homespring base must installed prior to the installation of the system. be utilized and securely anchored. Failure to do so may result in damage to the system and will void all Mounting warranties.
  • Page 25 Installation Depending on the particular installation, orient the cast iron stands in either a left-pointing or right-pointing system configuration. Connect the two cast iron cross members together using the three 1/4" x 1" bolts and lock nuts. Attach the two ends of the cross member assembly to the cast iron stands using the four 5/16"...
  • Page 26 System Installation for support, lift the opposite end of the bracket up, align the top mounting hole on the bracket assembly with the NOTE: Cut open the plastic bag before placing the system in pre-drilled hole on the wall stud, and secure the bracket the stand.
  • Page 27 Bracket Assembly (optional) figure 42 WARNING: Be sure to always verify Outlet Inlet and set backpulse tank pressure. Homespring must be Valve Valve empty when checking pressures. Outlet 20” (51cm) Do not pressurize The pressure may require adjustment depending on the water system of the home.
  • Page 28 Only plastic fittings can be installed horizontal mounting kit at the drain port of the system. Install in the Homespring. the drain solenoid valve to the 1/2" brass elbow using another Surface Water Kit not recommended on horizontal 1/2"...
  • Page 29 Fibre Chamber Air Vent Assembly Inlet Fitting Assembly: Backpulse Tank Follow the instructions in the Pipe Assembly and Installation Remove black section to assemble the inlet fitting assembly. If the surface plug at this ¼” NPT water option kit is installed, rotate the inlet solenoid valve port before installing Air Vent right-side-up.
  • Page 30 Final Plumbing Assembly For Systems That Have Both Flushing and Draining Sequences (Program 3 or 4): The system, when properly assembled, will appear as shown The draining sequence is non-pressurized. Because the system in figure 52. is completely emptied under only atmospheric pressure during the draining sequence, the entire drain line, including the floor drain, must be below the drain port of the system.
  • Page 31 Installing the Controller Mount the controller using the keyhole located at the back of the controller on the screw head. Level the controller. Remove the controller front cover and drill two additional WARNING: holes suitable for a #8 screw into these two holes and secure To ensure personal safety the controller to the wall by tightening the two screws.
  • Page 32 Setting the Controller Setting the Program NOTE: Electrical power to the controller must be ON to activate the flushing and draining sequences. The batteries Choosing a program: are for keeping the time in case of power failure and will not activate the flushing and draining sequences.
  • Page 33 Controller Functions Setting the Flush/Drain Interval: A. Manual Flush NOTE: For use when the instructions in this manual or the Owner's Manual call for a manual flush. To manually flush the system, press NEXT once. “MANUAL” flashes on the screen. Press MANUAL FLUSH to open the drain solenoid valve.
  • Page 34 Tighten the connection with the housing wrench. WARNING: For all surface water installations, the Homespring Certified Technician must The plumbing must be compatible with the inlet and inform the homeowner and home occupants that the outlet ports of the external prefilter.
  • Page 35: Commissioning - Horizontal

    F. COMMISSIONING - HORIzONTAL Slowly open the inlet valve half way, allowing water into the system. Avoid opening the inlet valve quickly as this will introduce air pockets that will take longer to escape. Keep the outlet valve closed. Check for any leaks in the plumbing. If WARNING: The system must be filled present, close the inlet valve immediately and repair.
  • Page 36 Cleaning With the Internal Prefilter still removed, unscrew the 1/2" brass plug on the air vent assembly near the backpulse tank. Ensure that the two mini ball valves are closed (to close, turn the handle perpendicular to the plug/hose end). Remove ”...
  • Page 37 The integrity test is conducted at initial open the valves. Confirm that the system pressure is zero. commissioning after the 15-minute flush and subsequent sanitization and on an annual basis by a Homespring qualified technician. Test Description...
  • Page 38 Error Displayed Corrective Action Plug the integrity tester into a power supply. Press the System pressure high, release System pressure is too high. scroll keys until the screen displays "Integrity Test". Press pressure Refer to Step 6 to release ENTER and use the scroll keys to choose “Horizontal”. pressure.
  • Page 39 Transmembrane Pressure (TMP) Test Remove the system cap using the cap wrench. Insert the The TMP test measures the pressure drop across the clean internal prefilter into the system prefilter cavity. Push membrane. This is the pressure change that the homeowner down gently to ensure it is seated properly.
  • Page 40: Annual Maintenance

    If needed pour the contents of the MC1 cleaning agent into A Homespring qualified technician must perform all a container with 250 ml (1 cup) of water. Mix thoroughly to maintenance including the annual integrity test as required dissolve the crystals.
  • Page 41 Cleaning the Stainless Steel Facade or Nameplate Transmembrane Pressure (TMP) Test If required, the surface may be cleaned using a mild soap solution. Do not use any other cleaners or abrasive materials Following a successful integrity test, with the system still on the stainless steel surface as these cleaners may damage flushing through a tap, the TMP must again be measured and the labels.
  • Page 42: Winterization Procedure

    H. WINTERIzATION PROCEDURE Drain the filtered water from the system by Tools/Supplies Required disconnecting the outlet stainless steel flex hose where it connects to the home plumbing, and drain into a large bucket. For all Systems you will need: Plug the flex hose and system by installing a 3/4" MNPT PVC plug.
  • Page 43 Spring Start-Up Following Winterization Remove the system cap and remove the prefilter. If the system is equipped with the carbon prefilter, discard the carbon prefilter. If the system is equipped with the stainless steel prefilter, clean and set aside the stainless steel prefilter WARNING: Do NOT allow the temporarily.
  • Page 44 System must soak Outlet Valve for 60 minutes. If the System is on ground or well water, the chlorine must be substituted with Homespring MC1 cleaning agent instead of chlorine bleach. Follow the directions on the Figure 79 package for preparing the MC1 cleaning agent.
  • Page 45: Troubleshooting

    The homeowner may notice a chlorine taste/smell when a tap is first opened for a day or two following this procedure. I. TROUBLESHOOTING If there are any problems with the Homespring Water Purifier System, contact your dealer or Homespring Customer Service immediately. Area Problem/Situation Corrective Action/Remedy Contact customer service.
  • Page 46 Area Problem/Situation Corrective Action/Remedy Pressure is too HIgH (greater than Release air from the air bladder valve on the backpulse tank by 35 psi) gently pushing in the valve stem. Checking Backpulse Tank Pressure Add air using a compressor or hand pump. Check the pressure Pressure is too lOW or NO pressure again in 15 minutes and before leaving the site.
  • Page 47: Specifications

    J. SPECIFICATIONS Controller Specifications Advanced Plus Controller Parameter UFC 211/ UF 211 • fuse - 3.0 Amp Maximum continuous flow rate 4.5 gpm (17 lpm) • Voltage In - 24 VDC Pressure drop at maximum continuous 5 psi (34.5 kPa)/ flow rate when new, at 25°C 4 psi (27.6 kPa) •...
  • Page 48: Frequently Asked Questions (Faq)

    K. FREQUENTLY ASKED QUESTIONS (FAQ) Front-flush - The controller opens the drain solenoid valve. The water supply line pressure causes an inrush What does the system do? of water into the System, scouring the surfaces of the membrane and expelling impurities through the drain. This system has been tested to significantly physically block Back-flush - At the same time, the air bladder inside the pathogens including bacteria, viruses and cysts from your...
  • Page 49 To maintain warranty, the system must be serviced by a other dissolved solids like essential minerals and fluoride. Homespring Certified Technician at least once per year. During this service, the system is cleaned and tested using the How long does the automatic cleaning cycle take?
  • Page 50: Replacement Part List And Procedures

    14. Label the box appropriately as in the table below. Call the section for how to perform a manual flush sequence. GE Homespring Consumer Products Customer Service for shipping and handling details at Turn off the tap and close the outlet valve.
  • Page 51 24 hours to avoid internal damage and allow a cause analysis to be completed. 30. Label the box appropriately as in the table below. Call the Homespring Consumer products Customer Service for shipping and handling details at 1-800-279-9404.
  • Page 52 C. INTERNAL PREFILTER REPLACEMENT (CARBON OR Using the housing wrench, loosen the external prefilter STAINLESS STEEL) housing from the external prefilter head. The carbon prefilter may require replacement more frequently Wear a pair of disposable gloves and carefully remove than once a year during the annual maintenance or if there the external prefilter cartridge from the external prefilter is a chlorine taste in the water after the system has been in housing.
  • Page 53 UFC 211 and UF 211 Series 17 18 FIGURE 20...
  • Page 54 UFC 211 and UF 211 Series Item Part Description UFC 211/ UF 211 Number System 3024924 Carbon Prefilter, 12” UFC models only 3024923 Stainless Steel Prefilter, 12” UF models 3024983 O-ring, 8” 2-443, EPDM, 70A, NSF61 3025097 Owner’s Manual 3035399 Advanced Plus Controller - DC 3025180 long Cap...
  • Page 55 Surface Water Option Kit Item Part Description Surface Number Water Option Surface Water Option Kit/External Prefilter Kit Parts 3024925 External Prefilter Replacement Cartridge 3024984 O-ring for External Prefilter 3025175 Reducer Bushing, 1" x 3/4" 3035503 Inlet Solenoid Valve, 3/4", Normally (CH21092) Open - DC 3030404...
  • Page 56: Homespring Water Purifier System Limited Warranty

    M. HOMESPRING WATER PURIFIER SYSTEM LIMITED WARRANTY Unless otherwise provided in a warranty for the specific product purchased, Seller hereby warrants that all goods purchased hereunder shall be free from material defects in material and workmanship for a period of one (1) year from the date of shipment to Buyer.