GE Homespring Operation Manual page 33

Water purifier system
Hide thumbs Also See for Homespring:
Table of Contents

Advertisement

4
Setting the Flush/Drain Interval:
Figure 59
1)
Press NEXT five times until "t:01" appears on screen.
2)
To change the flush/drain interval setting, press and
hold the UP and DOWN arrows together and press
NEXT. Release all buttons and repeat to shift to the next
interval. There are five interval settings to choose from:
No. of
Flush/Drain
Flush/Drain Cycles
Interval Setting
per Day
t:01
1 time
t:02
2 times
t:04
4 times
t:08
8 times
t:24
24 times
NOTE: Under conditions of turbid water and high usage of
the system, select a flush/drain interval setting appropriate
to the specific application. Increase frequency of flush/drain
cycle if the system TMP rises too quickly. Increasing the
number of flush/drain cycles per day will prolong the life of the
system; however, more water will be used for system cleaning
purposes.
Controller Functions
A. Manual Flush
NOTE: For use when the instructions in this manual or the
Owner's Manual call for a manual flush.
To manually flush the system, press NEXT once. "MANUAL"
flashes on the screen. Press MANUAL FLUSH to open the drain
solenoid valve. If the MANUAL FLUSH button is held down for
5 seconds, the drain solenoid valve will remain open for 5
minutes. To interrupt flushing, press MANUAL FLUSH again.
The drain solenoid valve will be closed automatically after 5
minutes if not interrupted.
B. Light and Alarm Function:
The green light on the controller indicates that the system is in
operation. The green light will be ON for 10 months from the
first commissioning of the system.
Time Interval Between
Flush/Drain Cycles
24 hrs
12 hrs
6 hrs
3 hrs
At the start of the system's 11th month of operation, the
1 hr
yellow service indicator light will come on. This is an indication
that the system's annual maintenance is required.
After 11½ months of operation, the yellow service indicator
light will begin to flash and an audible alarm will start to beep.
To temporarily silence the alarm, depress and hold the UP and
DOWN arrows together for three seconds. The alarm will come
back on in seven days after this command is executed.
To permanently turn the alarm off, depress and hold the UP
and DOWN arrows together and press ENTER. "A oF" (alarm
off) will appear on the screen. To turn the alarm on again,
repeat the above step. "A on" (alarm on) will appear on the
screen.
To reset the controller, press NEXT and ENTER together and
hold for three seconds. The yellow light will go off and the
green light will come on again.
WARNING:
indication of the integrity of the membrane inside the
system.
The green light is NOT an