GE Homespring Operation Manual page 22

Water purifier system
Hide thumbs Also See for Homespring:
Table of Contents

Advertisement

System Configuration for Standard Installations
For households on a municipal system, locate the water
main, which connects the household to the municipal supply
line. Usually this is near the water meter. For private pump/
pressure tank style systems, locate the outlet of the pressure
tank. The system must be installed downstream of the water
meter or pressure tank in order to provide treated water to the
whole household.
The system is installed directly in-line with the home supply,
following the water meter or pump and pressure tank.
Diverted Line for non-
filtered water
outlets.
(e.g. Exterior taps)
1. Inlet Valve
2. Bypass Valve
3. Outlet Valve
4. Drain Solenoid Valve
5. Drain Hose
6. Advanced Plus Controller
NOTE: A dedicated line, diverted from the main water line,
may be installed upstream of the system for all exterior taps,
pool or hot tub makeup valves, and irrigation systems. This
arrangement will extend the life of the system membrane.
22
24 VDC
figure 32
System Configuration for Optional Surface
Water Option Kit
Systems purchased with the surface water option kit are
installed at the same location and in the same manner as a
standard system, with the exception of additional parts, which
must be installed, as shown. Additional parts include an inlet
solenoid valve, check valve, and external prefilter.
1. Inlet Valve
2. Bypass Valve
3. Outlet Valve
4. Drain Solenoid Valve
5. Drain Hose
6. Advanced Plus Controller
7. Inlet Solenoid Valve
8. Check Valve
9. External Prefilter
figure 33
NOTE: The inlet solenoid valve of the surface water option kit
creates a non-pressurized draining of the system. The entire
drain line, including the floor drain, must be below the drain
port of the system.
WARNING:
water sources, an external prefilter of 20-microns
(e.g. Pentek S1-20BB) nominal micron size is required.
Failure to provide this level of prefiltration may lead to
system damage and will void the warranty. A damaged
system may cause serious personal injury, illness, and/
or death.
Tools, Supplies and Parts
WARNING:
system should be maintained in sterile condition so that
the risk of cross-contamination is minimized. Bacteria,
parasites, and viruses can live for long periods of
time. As a result, dangerous organisms can be carried
from one installation or maintenance site to another
and may potentially cause serious personal injury,
sickness and/or death. Proper tool care and disinfection
procedures will minimize these risks.
24 VDC
When treating surface
Tools used to install the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Homespring ufc 211 seriesHomespring uf 211

Table of Contents