Vacuum Switch - Quadra-Fire SANTA FE Owner's Manual

Table of Contents

Advertisement

R
6. Fuse
The fuse is located on the side of the junction box above
to the red call light. The fuse will blow should a short occur
and shut off power to the appliance.
7. Heat Output Switch
The heat output switch is located on the upper right back
panel. The function of the heat output switch is to regulate
the burn rates; low, medium and high settings.
8. Hopper Switch
The hopper switch is located in the upper right hand corner
of the hopper. This switch is designed to shut down the
feed motor whenever the hopper lid is opened.
9. Igniter
The igniter is mounted on the base of the firepot.
Combustion air travels over the red hot igniter creating
super heated air that ignites the pellets.
10. Junction Box And Wiring Harness
The junction box is located on the lower left side of the
appliance, behind the left side panel. The junction box and
wiring harness are replaced as one component.
11. Power Supply
The power outlet is located behind the control box on the
back of the appliance, lower left corner. Check the wall
receptacle for 230 volt, 50 Hz (standard current). Make
sure the outlet is grounded and has the correct polarity. A
good surge protector is recommended.
Red Call Light
12.
The red call light is on the side of the junction box, below
the fuse. The function of the red call light is to indicate that
the thermostat is calling for heat.
Reset Button
13.
The reset button is located on the back of the appliance in
the upper right corner below the heat output control switch.
The function of the button is to momentarily open the
thermostat circuit, which restarts the system.
Page 32
14. Thermocouple
The thermocouple is located on top of the firepot inside
the thermocouple cover (ceramic protection tube). The
thermocouple sends a millivolt signal to the control box
indicating the preset temperatures of the green and red
lights have been obtained.
15. Thermostat (Optional)
The appliance has the option to be run off a thermostat. For
the The heat anticipator should be set on the lowest setting
available.
16. Snap Disc #1 (Convection Blower) 43°C
Snap disc #1 is located on the right side of the appliance
behind the right side panel. There are 2 purple wires
connected to it. This snap disc turns the convection blower
on and off as needed. Power is always present at snap disc
#1.
17. Snap Disc #2 (Fuel Delivery Interrupt) 79°C
Snap disc #2 is located on the centre of the convection
plenum above the convection blower. There is an orange
and a black wire connected to it. This snap disc will turn
off the feed system which will turn off the appliance if
an over fire condition should occur or if the convection
blower should fail to operate. If this occurs you will have to
manually reset the snap disc.
18. Snap Disc #3 (Back Burn Protector) 121°C
Snap disc #3 is mounted on the back of the auger tube in
the centre of the appliance and has a reset button. There
are two grey wires connected to it. To access it remove the
right side panel. If the fire tries to burn back into the feed
system or push exhaust up the feed tube, this snap disc
will shut the entire system off. This disc must be manually
reset.

19. Vacuum Switch

The vacuum switch is located on the lower right side of the
appliance behind right side panel. There are two red wires
attached to it. This switch turns the feed system on when
vacuum is present in the firebox. The vacuum switch is a
safety device to shut off the feed motor if the exhaust or the
heat exchanger system is dirty or plugged or if the firebox
door is open.
7068-114B