Advanced PSTN Configuration

10.1 Mediant 2000 Clock Settings

The gateway can either generate its own timing signals, using an internal clock, or recover them
from one of the E1/T1 trunks.
a. To use the internal gateway clock source configure the following parameters:
TDMBusClockSource = 1
ClockMaster = 1 (for all gateway trunks)
b. To use the recovered clock option, configure the following parameters:
TDMBusClockSource = 4
ClockMaster_x = 0 (for all 'slave' gateway trunks connected to PBX#1)
ClockMaster_x = 1 (for all 'master' gateway trunks connected to PBX#2)
Assuming that the gateway recovers its internal clock from one of the 'slave' trunks connected to
PBX#1, and provides clock to PBX#2 on its 'master' trunks.
In addition it is necessary to define from which of the 'slave' trunks the gateway recovers its clock:
TDMBusPSTNAutoClockEnable = 1 (the gateway automatically selects one of the connected
'slave' trunks)
Or
TDMBusLocalReference = # (Trunk index: 0 to 7, default = 0)
Note 1:
Note 2:

10.2 ISDN Overlap Dialing

Overlap dialing is a dialing scheme used by several ISDN variants to send and / or receive called
number digits one right after the other (or several at a time). As opposed to the enbloc dialing
scheme in which a complete number is sent.
The Mediant 2000 can optionally support ISDN overlap dialing for incoming ISDN calls for the
entire gateway by setting 'ISDNRxOverlap' to 1, or per E1/T1 span by setting 'ISDNRxOverlap_x'
to 1 ('x' represents the number of the trunk, 0 to 7).
To play a Dial tone to the ISDN user side when an empty called number is received, set
'ISDNINCallsBehavior = 65536' (bit #16) causing the Progress Indicator to be included in the
SetupAck ISDN message.
The Mediant 2000 stops collecting digits (for ISDN IP calls) when:
The sending device transmits a 'sending complete' IE in the ISDN Setup or the following Info
messages to signal that no more digits are going to be sent.
The inter-digit timeout (configured by the parameter 'TimeBetweenDigits') expires. The
default for this timeout is 4 seconds.
Version 4.6
To configure the TDM Bus Clock Source parameters, refer to Section
page 91.
When the Mediant 2000 is used in a 'non-span' configuration, the internal
gateway clock must be used (as explained above).