Leica DNA03 User Manual page 19

Hide thumbs Also See for DNA03:
Table of Contents

Advertisement

The following options are available for the evalua-
tion of levelling data:
Display, editing and evaluation of single line
levelling
Creating and adjusting1D height grids.
Further information on the LGO will gladly be given
by your local Leica representative.
Data flow:
We recommend using the XML-format to transfer
measurement data from the DNA to the LGO and its
modules. The required Format file (DnaXml.frt) is
located on the supplied CD and can be installed on
the instrument with the "Data Exchange Manager".
The transfer of job data from the instrument
to the computer is then also done through
the "Data Exchange Manager".
As LGO / LevelPak-Pro read in *.lev files by default,
we recommend giving the file to be transferred to
the computer a *.lev name. The following input
mask is displayed in the LGO Data Exchange
Manager when transferring data to the computer. As
an example, the format file DNAXml5 was selected.
We advise against transferring measured data in
GSI format from the level to the LGO software pak-
kage. As the GSI format does not include all infor-
mation, errors may occur during height calculations
and lead to wrong results.
Transferring measurement data from the level test
from the DNA to LGO is also not recommrnded in
XML format.
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dna10

Table of Contents