Hanna Instruments HI 935005 Instruction Manual

Hanna Instruments HI 935005 Instruction Manual

Portable k-thermocouple thermometers
Hide thumbs Also See for HI 935005:

Advertisement

99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com
Instruction Manual
HI 935005 - HI 935005N
HI 935002 - HI 935009
Portable K-Thermocouple
Thermometers

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI 935005 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hanna Instruments HI 935005

  • Page 1 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.TestEquipmentDepot.com Instruction Manual HI 935005 - HI 935005N HI 935002 - HI 935009 Portable K-Thermocouple Thermometers...
  • Page 2: Table Of Contents

    When shipping any instrument, make sure it is properly packaged for complete warranty. protection. HI 935005 has been designed for laboratory and field use, while HI 935005N is suitable for high accuracy (meter and probe can be TABLE OF CONTENTS calibrated in an ice bath at 0°C) or dimly lit areas (the backlight...
  • Page 3: Specifications Of Hi 935005 And Hi 935005N

    • Remaining battery life indication / low battery detection the Calibration mode (with reading within ±3°C range); press to abort the Calibration mode. • Waterproof casing • Auto-off capability (HI 935005 only) • Backlight feature (HI 935005N only) • User calibration at 0°C (HI 935005N only)
  • Page 4: Specifications Of Hi 935002 And Hi 935009

    SPECIFICATIONS OF HI 935002 & HI 935009 HI 935002 HI 935009 SPECIFICATIONS Range (*) -50.0 to 199.9°C / 200 to 1350°C -58.0 to 399.9°F / 400 to 2462°F Resolution 0.1°C (up to 199.9°C) / 1°C (outside) 0.1°F (up to 399.9°F) / 1°F (outside) Accuracy ±0.2% full scale (@20°C/68°F)
  • Page 5: Operational Guide

    °C/°F key or (ALT+) °C/°F keys, AUTO SHUT-OFF (HI 935005 and HI 935009) To save battery life, the HI 935005 and HI 935009 models are provided with an auto-off feature, which switches the instrument off HI 935005 / 5005N HI 935009 after a certain period of nonuse.
  • Page 6 HI 935009 allows the user to select the auto-off time period through 2-CHANNEL MODELS (HI 935002 and HI 935009) the front keyboard; press (ALT+) AOFF to enter the mode, then set HI 935002 and HI 935009 models can monitor two samples through the desired auto shut-off interval (8 min, 60 min, or disabled) with two independent temperature channels (probes).
  • Page 7: User Calibration

    USER CALIBRATION BATTERY REPLACEMENT The HI 935005N and HI 935009 models can be calibrated at 0°C by When the battery level is below 10%, a warning using an ice bath. symbol will blink on the LCD to indicate a low battery condition.
  • Page 8: Accessories

    ACCESSORIES K-TYPE THERMOCOUPLE PROBES OTHER ACCESSORIES HI 710002 Soft carrying case with integral handle, 1 m (3.3') cable & mini-connector: HI 710009 Blue rubber boot HI 766A Roller surface probe, max 320°C/600°F HI 710010 Orange rubber boot HI 766B Surface probe, max 650°C/1200°F HI 710031 Hard carrying case HI 766B1...