Microprocessor-based thermocouple thermometers
Hide thumbs Also See for HI 93530:

Advertisement

Instruction Manual
HI 93530 - HI 93531
HI 93532 - HI 93551
HI 935005 - HI 935006
HI 935007
Microprocessor-based
Thermocouple Thermometers
These Instruments are in
h t t p : / / w w w . h a n n a c a n . c o m
h t t p : / / w w w . h a n n a c a n . c o m
Compliance with the CE Directives

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HI 93530 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hanna Instruments HI 93530

  • Page 1 Instruction Manual HI 93530 - HI 93531 HI 93532 - HI 93551 HI 935005 - HI 935006 HI 935007 Microprocessor-based Thermocouple Thermometers These Instruments are in h t t p : / / w w w . h a n n a c a n . c o m h t t p : / / w w w .
  • Page 2: Table Of Contents

    TABLE OF CONTENTS TABLE OF CONTENTS Preliminary Examination ......3 General Description ........3 Functional Description and Specifications of HI 93530 ......5 Functional Description and Specifications of HI 93531 ......6 Functional Description and Specifications for HI 93532 ......7 Functional Description and Specifications of HI 93551 ......
  • Page 3: Preliminary Examination

    PRELIMINARY EXAMINATION WARRANTY Remove the instrument from the packing material and examine it carefully to make All Hanna Instruments meters are warranted sure that no damage has occurred during for two years against defects in workman- shipment. If noticeable damage is evident, ship and materials when used for their in- notify your Dealer.
  • Page 4 • Two year Warranty 0.06" • Possibility of switching between the Cen- tigrade and the Fahrenheit scale (for HI 93530, HI 93531, HI 93551, HI 935005, HI 766F1 Flexible probe without handle, max HI935007 only) 480°C/900°F • HOLD function that freezes the reading...
  • Page 5: Functional Description And Specifications Of Hi 93530

    FUNCTIONAL DESCRIPTION AND HI 766B1 90° surface probe, max 450°C/840°F SPECIFICATIONS OF HI 93530 30mm 1.2" 300mm 11.8" ins rum n s °C HI 766B2 Surface probe, max 900°C/1650°F K-THERMOCOUPLE THERMOMETER 0.3" RANGE: -200°C to 1370°C -300°F to 2500°F 130mm 5.1"...
  • Page 6: Functional Description And Specifications Of Hi 93531

    FUNCTIONAL DESCRIPTION AND HI 766PE1 General use probe, max 900°C/1650°F SPECIFICATIONS OF HI 93531 155mm 6.1" 0.12" ins rum n s °C K-THERMOCOUPLE THERMOMETER HI 766PE2 General use probe, max 900°C/1650°F 200mm 7.8" 0.20" MEM• HOLD °C °F HI 93531 HI 766HD Rugged thermocouple probe handle with 1 m (3.3' ) cable fitted with a mini- connector...
  • Page 7: Functional Description And Specifications For Hi 93532

    FUNCTIONAL DESCRIPTION AND ACCESSORIES SPECIFICATIONS FOR HI 93532 K-Type Thermocouple Probes with detachable handle & mini-connec- tor (to be plugged into HI 766HD probe handle): ins rum n s °C HI 766PA Roller surface probe, max 320°C/600°F K-THERMOCOUPLE (DUAL INPUT) THERMOMETER MEM•...
  • Page 8: Functional Description And Specifications Of Hi 93551

    FUNCTIONAL DESCRIPTION AND SHOCKPROOF RUBBER BOOTS SPECIFICATIONS OF HI 93551 These rubber boots are specially made to prolong the life of your instruments and to ins rum n s prevent damage due to accidental falls. °C They measure 155 x 90 x 45 mm (6.1x3.5x1.8") and are available in two dif- K-THERMOCOUPLE THERMOMETER...
  • Page 9: Functional Description And Specifications Of Hi 935005

    RANGE: -50°C to +950°C When the battery is low the user is warned by the word "BAT" (for HI 93530, HI 93531, HI 93532, HI 93551) or "Eb" (for HI 935005, H I 9 3 5 0 0 6 a n d H I 9 3 5 0 0 7 ) o n t h e instrument's display.
  • Page 10: Functional Description And Specifications Of Hi 935006

    FUNCTIONAL DESCRIPTION AND DISPLAY CODES GUIDE SPECIFICATIONS OF HI 935006 Display Description HI 93530, HI93531, HI 93532, HI93551: ins rum n s °C ---- The probe is not connected to the instrument or the reading is out of range RANGE: -80.0°C to +400°C...
  • Page 11: Functional Description And Specifications Of Hi 935007

    (see page 20). AUTO-SHUT OFF To save battery life, HI 935006 will switch off after 5 minutes and HI 93530, HI 93531, HI 93532, HI 93551, HI 935005 and HI935007 after 60 minutes. The switch located in the battery compart- ment enables this feature (for all models except of HI 935006).
  • Page 12: Operational Guide

    After the test, the thermometer will switch to the measurement mode. If a temperature probe is plugged in, the unit will display the temperature. For HI 93530, HI 93531, HI 93532, HI 93551 TEMPERATURE DIFFERENCE ( for If the probe is not plugged...
  • Page 13 MEMORY FUNCTION (HI93531 and HI 93532 MEASURING SCALE (°C/°F)(for HI93530, only) HI93531, HI93551, HI935005, HI935007 only) The memory & hold function is activated by When the meter is turned on, it automati- MEM HOLD. cally defaults to the °C scale. Measurements can be performed on either the Centigrade The measured temperature is stored in or the Fahrenheit scale.
  • Page 14 HOLD key. perature by pressing the respective HI or LO key. For HI 93530 and HI 93551 only The appropriate display indicator, "HI" or To freeze the measured temperature on the "LO", will light up together with the value display, press and hold the HOLD key.