HI-LIMIT THERMOSTAT
The hi-limit thermostat in an electric
dryer is located on the heat cone. It is
many times referred to as the safety
thermostat. This thermostat is located
close to the heating element and in the
event of an overheating condition, will
cycle the heat off qUickly. If a dryer is
found to be cycling on the hi-limit,
check for an air flow restriction.
To replace:
1. Remove front panel.
2. Loosen back screw.
3. Remove front screw.
4. Remove wires and slide thermostat
out.
ED/GD401
1090
INLET DUCT
To replace the inlet duct, it will be nec-
essary to remove tumbler rear. The
inlet duct is secured to the tumbler rear
by three screws, one at the top and two
at the bottom under the felt seal.