TWO SUPPLY WATER TEMPERATURE REQUIREMENT
Handled as the priority zone on multi-zone (EB-ZEA-1) or two
pump (EB-Z2P) controllers
Priority switch on, zone 1 active - TS boiler automatically changes
to 150° (or selection 176°) supply water setting
All other zones are held off
With zone 1 satisfi ed or 60-minute timeout, the boiler automatically
returns to the preset temperature and reacts to the other zones
INSTALLATION PLUMBING KITS
These installation kits provide the critical plumbing components needed for easy installation of the Electro-Boiler. In addition to the
items shown in the matrix below, each kit includes all necessary ball valves, drain valve, tees, elbows, nipples, bushings, couplings,
etc. for direct connection to circulator pump and/or manifold.
Electro Industries' boilers come standard equipped with outlet temperature/pressure gauge, pressure relief safety valve, and when
applicable, the WarmFlo
TM
Model
EMB-BK
EMB-PK
EB-PK-M
EB-MS, -MA, -MO Series
EB-BK-TS
EB-S, -WA, -WO Series
EB-PK-TS
EB-S, -WA, -WO Series

CIRCULATING PUMPS

5585 - Mini-Boiler &
10 kW TS Series
120V, 1/25 HP, maintenance-free wet
rotor circulator
Pump curve example - 5 GPM (19 L)
@ 11 ft. of head (32.9 kPa)
07/24/2007
electronic control sensors. These kits provide the additional components for easy installation:
Application
Return Gauge
All EMB Series
All EMB Series
5586 - TS Series, Standard
120V, 1/6 HP, maintenance-free oil
lubricated circulator
Pump curve example - 10 GPM (37.8 L)
@ 20 ft. of head (50.8 kPa)
Low Temp
Radiant, slab
Radiant, staple up
Radiant, slab
Baseboard
Radiant, slab
Fan coil
Radiant, slab
Water heater, side arm
Radiant, slab
Hanging unit heater (garage, shop, etc.)
Expansion Tank
2.1 gal. (7.9 L), 40,000 Btu/h
2.1 gal. (7.9 L), 40,000 Btu/h
4.5 gal. (17 L), 135,000 Btu/h Enhanced air separator, EAS
4.5 gal. (17 L), 135,000 Btu/h
4.5 gal. (17 L), 135,000 Btu/h Enhanced air separator, EAS
Two fl anges, with isolation valve
High Temp
Air Vent
Basic fl oat type
Enhanced air separator, EAS
Basic fl oat type
5578 - 3/4" Pipe
5582 - 1" Pipe
5579 - 1-1/4" Pipe

BL001