Whirlpool Rooper Service Manual page 58

Freestanding standard electric range
Table of Contents

Advertisement

6 " & 8 " COIL ELEMENTS
Test Procedure
WARNING
Electrical Shock Hazard
Disconnect from electrical supply before ser-
vicing unit.
Failure to do so could result in death or
electrical shock.
Whirlpool
Part No.
3195919
3196204
3195918
3196205
Number
Wattage
Voltage
of Turns
(Nom.)
208/240
3
940 / 1250
208 / 240
4
1130 / 1500
208 / 240
4
1575 / 2100
208 / 240
5
1955 / 2600
208 / 240
To test a coil element, perform the following
steps:
1.
Use an ohmmeter and set the range switch
to R x 1.
2.
With no power applied, unplug the coil
element from the terminal block.
3.
Touch the leads of the ohmmeter to the
terminals of the coil element and mea-
sure the resistance (see the chart below
for the correct reading for the coil you are
testing).
If the above results are not obtained, the ele-
ment is defective and should be replaced.
Element
Hot Watts
Size
@ 240V –10% +5%
6"
1125 - 1312
6"
1350 - 1575
8"
1890 - 2205
8"
2340 - 2730
4-6
Cold Ohms
Resistance
42 - 50
35 - 41
25 - 30
20 - 24

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rf302oxe wRf302bxeRf315pxeRf324pxeRf325pxe

Table of Contents