COM1 Tab

Start > Settings > Control Panel > Data Collection > COM1
This panel sets communication parameters for any device connected to the external port.
Adjust the settings and click the OK button to save the changes. Any changes take effect immediately.
This panel does not configure the connected device. Please refer to the documentation for the external connected or wireless
mobile device for information on configuring the device.
Note:
The MX7 Tecton does not support 5V switchable power on Pin 9 for tethered scanners. Tethered scanners can send
data to the MX7 Tecton when they are connected to a powered cradle serial port and the MX7 Tecton must be in the
cradle.
Integrated laser scanner default values are 9600 Baud, 8 data bits, 1 stop bit and No parity. If these values are changed, the
default values are restored after a cold boot or reflashing.
4-85