(2) Dehumidifying Mode

1. Conditions and processes of dehumidifying operations: Same as the cooling mode;
2. The temperature setting range is: 16~30 ;

(3) Air-supplying Mode

1. The compressor, outdoor fans and four-way valves are switched off;
2. The temperature setting range is: 16~30 .

(4) Heating Mode

1. Conditions and processes of heating operations: (T
of indoor environment thermo-bulb,
compensation during heating operations)
(1) If the compressor is shut down, and [(T
T
] ≤ 0.5 , start the machine to enter into heating operations for heating;
setup
(2) During operations of heating, if 0
T
] < 2 , the heating operation will be still running;
setup
(3) During operations of heating, if 2
T
], the heating operation will stop after reaching the temperature point.
setup
2. The temperature setting range in this mode is: 16~30 .

3. Special Functions

(1) Defrosting Control
1. Conditions for starting defrosting
After the time for defrosting is judged to be satisfied, if the temperature for defrosting is satisfied after
detections for continuous 3minutes, the defrosting operation will start.
4. Control Logic
(1) Compressor Control
Notes:
In all modes: once the compressor starts up, it will not be allowed to stop until having run for the [t
] (Note: including cases of shutdown when the temperature point is reached; except the cases requiring
running time
stopping the compressor such as fault protection, remote shutdown, mode switching etc.);
In all modes: once the compressor stops, it will be allowed be restart after 3-minute delay (Note: The inner units
have a function of power memory, the machine can be restarted after remote shutdown and powering up again
without delay).
1. Cooling mode
Start the machine to enter into cooling operation for cooling, the compressor is switched on.
2. Dehumidifying mode
Same as the cooling mode.
3. Air-supplying mode
The compressor is switched off.
4. Heating mode
(1) Start the machine to enter into heating operation for heating, the compressor is switched on.
(2) Defrosting:
a. Defrosting starts: the compressor is shut down, and restarts it after 55-second delay.
b. Defrosting ends: the compressor stops, then starts it after 55-second delay.
(2) Outer Fans Control
Notes:
Only the outer fans run for at least 80s in each air flow speed can the air flow be switched;
After the outer fans run compulsively in high speed for 80s when the machine starts up, control the air flow
according to the logic.
After remote shutdown, safety stops, and when the machine stops after reaching the temperature point, as well
as after the compressor stops, extend 1 minute, the outer fans will stop (During the period in the 1 minute, the air
flow of outer fans can be changed according to the outdoor ambient temperature changes);
When running with force, the outdoor fans shall run in the highest air flow.
1. Outer fans control logic in cooling/dehumidifying mode:
(1) If T
outdoor ambient temperature
(2) If T
outdoor ambient temperature
T
heating indoor ambient temperature compensation
indoor ambient temperature
≤ [(T
indoor ambient temperature
≤ [(T
indoor ambient temperature
≥ [T
inlet temperature in high cooling air flow
≤ [T
inlet temperature in low cooling air flow
is the actual detection temperature
indoor ambient temperature
is the indoor ambient temperature
T
heating indoor ambient temperature compensation
T
heating indoor ambient temperature compensation
T
heating indoor ambient temperature compensation
], the outer fans will run in high air flow speed;
], the outer fans will run in low air flow speed;
) –
) –
) –
min. compressor