Defrosting Control Under Heating Mode; 4-Way Valve Control; Charging Control; Pfc Function Control - ComfortStar CARAT18-CD Service Manual

23seer diamond splits
Table of Contents

Advertisement

(3) During the process of operation, if
, the outer fans will keep the former operation air damper;
temperature of Cooling
(4) Control of oil return during cooling: when the outer fans run 80s at a high speed, you should regulate it
with control logic (the control which priority level is 80s higher than the air damper switch cycle)
2. The outer fan will stop working under the supply air mode.
3. The control logic of outer fans under the heating mode:
(1) If T
T
outer ring
high air-damper inlet temperature of heating
(2) If T
≥ T
outer ring
high air-damper inlet temperature of heating
(3) During the process of operation, if
, the outer fans will keep the former operation air damper;
temperature of heating

(4) Defrosting control under heating mode:

a. Defrosting begins: The outer fans will stop working after 50s of entering into the defrosting compressor.
b. Defrosting stops: The outer fans will begin to work when exit the defrosting compressor.
(5) Oil return control under heating mode:
The outer fans will be regulated according to normal control logic.

(3) 4-way valve control

1. The 4-way valve control under the modes of Cooling, dehumidification and supplying air: closing;
2. The status of 4-way valve control under the heating mode: getting power;
(1) Charging circuit control of outer engine electrolytic capacitor

1. Charging control

(1) Charging begins:
When receiving the order of power turn on or preheating, it will carry out charging control at first;
(2) Charging stops:
Charging will stop if meet the two following conditions:
a. The preheating of compressor has been closed for 30 min;
b. Switched to the power turn-off mode or supplying air mode for 10 min.
2. Capacitance short-circuit protection (short trouble under DC Power)
When the DC Power busbar voltage is measured lower than 100v after 2s of pulling in the charging relay,
you should cut down the charging relay immediately; and carry on the above operation after 30s, if the
capacitance short circuit was judged for two times, it shows that the machine has DC Power short trouble,
and can't be resumed.

(5) PFC function control

1. Power frequency checking (suitable for Semi-active PFC control):
(1) When power on, you continually measure power cycling fit for185 ms
within 2s, then you can confirm that the power frequency is 50 HZ, and you should control the PFC
according to the 50 Hz power parameter.
(2) When power on, you continually measure power cycling fit for 151 ms
with 3s, then you can confirm that the power frequency is 60 HZ, and you should control the PFC according
to the 60 Hz power parameter.
(3) If the power cycling T doesn't meet conditions (1) and (2), and doesn't have trouble at the normal mode,
we shouldn't start PFC, but start the compressor normally. If it has the PFC trouble at the testing mode and
can't be resumed, it is only removed after cut the power. Both of the compressor and PFC shouldn't be
started.
5. The protection functions of controller
(1) Evaporator frozen-preventing protection function
At the mode of Cooling, dehumidifying:
Evaporator frozen-preventing protection function is allowed to begin after 6 min of starting the compressor.
T
low air-damper inlet temperature of Cooling
, the outer fans will run at high air flow speed;
, the outer fans will run at low air flow speed;
T
high air-damper inlet temperature of heating
T
T
outer ring
high air-damper inlet
T
T
outer ring
low air-damper inlet
T
215 ms for 10 times
power
T
181 ms for10 times
power

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Carat24-cd

Table of Contents