Arming Information

Delay Doors and Delay Time Settings
When the system is armed, enter and exit the premises
only through designated delay doors.
The time allowed to enter the premises and disarm the sys-
tem is the Entry Delay time.
The time allowed to leave the premises after arming the
system is the Exit Delay time.
Door Door Location
1
2
3
4
5
Feature
My system features include:
q Yes. Press the arming level desired.
Quick Arm
q No. Enter arming level, then access code.
q Yes. Press
Quick Exit
mises through a delay door within 2 min-
utes.
q No. I need to disarm my system in order to
exit the premises.
q Yes. If I reenter the armed premises during
Exit
Extension
the Exit Delay time, the Exit Extension
will begin.
q No. If I reenter the armed premises during
the Exit Delay time, it will continue to
count down and I must disarm the system.
q Yes. I can use a key to arm the system. The
Keyswitch
Arming
switch is located:
_______________________________
_______________________________
q No.
q Yes. If, after arming to Level 3—AWAY, I
Auto STAY
Arming
don't exit through a designated delay door,
the system will arm to Level 2—STAY.
q No. If, after arming to Level 3—AWAY, I
don't exit through a designated delay door,
the system will continue to arm to Level
3—AWAY. And, if my system contains
motion detectors, movement may cause an
alarm.
20
Entry
Exit
Dela
Dela
y
y
:
:
:
:
:
:
:
:
:
:
D
and exit your armed pre-

Paging

For what events will the central station or pagers be noti-
fied?
Reporting Features
High Level Reports
Low Level Reports
Opening/Closing Reports
Latchkey Reports
Is the Streamlining feature enabled?
q
Yes. When the system pages me, the message
will not include the central station account num-
ber.
q
No. All pages from my system will include the
account number.
q
According to my pager provider, the central sta-
tion account number will appear as:
_______________________________________

If the Power Goes Out

Your system has a backup battery that keeps your system
operational during a power failure. An optional feature
allows your system to alert the central monitoring station
if the power is off for more than 15 minutes. It reports
again when power has been restored.

No Activity Time

My system uses the No Activity feature.
q
Yes. If there is no activity in my system for ____
hours (1-42, default 24), the system will send a
No Activity report to the Central Station.
q
No. My system setup does not include this fea-
ture.

System Information

System Information
Code
Factory code
System number
System level
Pagers
CS 1
CS 2
1
2
N/A
N/A
3

Hide quick links:

Advertisement

Table of Contents
loading