Security systems
Hide thumbs Also See for Concord express:
Table of Contents

Advertisement

Device
Test Procedure
Touchpads
Send a:
q Police panic alarm,
q Fire panic alarm, and
q Auxiliary panic alarm.
Wireless Touchpads
Press the Bypass key.
Keychain Touchpads
Press and hold Lock and Unlock simultaneously for 3
seconds.
Panic buttons
Press and hold the appropriate panic button(s) for 3 full
seconds.
Door/window sensor
Open the secured door or window.
Smoke detector
Press and hold the test button until the system sounds
transmission beeps.
Motion detector
Avoid the motion detector's view for 5 minutes, then
enter its view.
Rate-of-Rise Heat
Rub your hands together until warm, then place one
Detector
hand on the detector for 30 seconds.
(Not UL investigated)
Shock sensor
Tap the glass twice, away from the sensor. Wait at least
(Not UL investigated)
30 seconds before testing again.
Glass guard sensor
Tap the glass 3 or 4 inches from the sensor.
(Not UL investigated)
Freeze sensor
Apply an ice cube wrapped in plastic to the sensor.
(Not UL investigated)
Do not allow the sensor to get wet.
.
Table 1. Testing Sensors and Zones
Touchpad Result
q Touchpad Panic POLICE
q Touchpad Panic FIRE
q Touchpad Panic AUXILIARY
q POLICE PANIC OK
q FIRE PANIC OK
q AUXILIARY PANIC OK
q Zones nn OK
q Touchpad nn OK
q Zones nn OK
q SENSOR nn OK
OR
q Touchpad Panic POLICE
q POLICE PANIC OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
q Zones nn OK
q SENSOR nn OK
Testing the System
OK
OK
OK
OK
15