FUEL CONSUMPTION (IN GALLONS PER HOUR):
LOAD
GASOLINE
NO
HALF
FULL
2.9

FUEL REQUIREMENTS (LP UNITS)

These generators are equipped with a liquefied petro-
leum (LP) gas fuel system. LP gas is usually supplied
as a liquid in pressure tanks.
These generators require a "vapor withdrawal" type
fuel system. This type of gaseous fuel system uses
the vapors forming above the liquid fuel in the stor-
age tank. Air temperature around the storage tank
must be high enough to sustain adequate fuel vapor-
ization. In colder climates, you may need to use an
independent heat source to be sure the fuel suffi-
ciently vaporizes in the storage tank.
LP gas may consist of propane, butane or a mixture
of the two gases. Propane vaporizes at temperatures
as low as -20°F (-29°C), but butane returns to its liq-
uid state when the temperature drops below about
32°F (0°C). For that reason, a higher ratio of propane
is desired in the gas mixture when temperatures
drop below freezing.

2.10 ENGINE OIL REQUIREMENTS

The recommended oils include the following:
• During summer months: SAE 30. An acceptable
substitute is SAE 10W-30.
• During winter months: SAE 5W30. DO NOT USE
SAE 10W-40.
Crankcase and oil filter capacity is about 950ml or
one (1) quart.
Use no special additives.
"Maintenance" section for oil level check and fill pro-
cedures.
IMPACT-36 plus II Recreational Vehicle Generator
LP
0.14
0.20
0.32
0.41
0.54
0.77
Section 2 – Operation

2.11 GAS GENERATOR SPECIFICATIONS

Model ..................................................Impact-36G plus II
Rated Maximum Continuous
AC Power Output ..............................3600 watts (3.6 kW)
Rated Voltage ................................................120 volts AC
Rated Maximum Continuous
Current at 120 volts ..................................30 AC amperes
Phase ............................................................Single Phase
Rated AC Frequency ................................................60 Hz.
Recommended Battery
Cranking Current ..............................................400 amps
Gross Weight ............................................................97 lbs
Maximum Cranking Current..............................250 Amps
Maximum Charging Current ..................................2 Amps

2.12 LP GENERATOR SPECIFICATIONS

Model ..............................................Impact-36LPG plus II
Rated Maximum Continuous
AC Power Output ..............................3400 watts (3.4 kW)
Rated Voltage ................................................120 volts AC
Rated Maximum Continuous
Current at 120 volts................................28.3 AC amperes
Phase ............................................................Single Phase
Rated AC Frequency ................................................60 Hz.
Recommended Battery
Cranking Current ..............................................400 amps
Gross Weight ............................................................99 lbs
Maximum Cranking Current..............................250 Amps
Maximum Charging Current ..................................2 Amps

2.13 ENGINE SPECIFICATIONS

Type of Engine ......................................................GN-220
Cooling Method ..................................................Air-cooled
Displacement............................................................220cc
Type of Governor ..............................................Electronic
Air Cleaner ..................................................Paper element
Starter ..................................................12 volt DC electric
Ignition System ................................................Solid state
Recommended Spark Plugs ................Champion RC12YC
Spark Plug Gap ..................................0.030 inch (0.8mm)