B. Design and Installation Considerations
NOTICE:
Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, fi re
offi cials or authorities having jurisdiction over restrictions,
installation inspection and permits.

1. Selecting Fireplace Locations

This fi replace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fi replace in a basement, near frequently
opened doors, central heat outlets or returns, or other
locations of considerable air movement can affect the
performance.
Outside air must be used for combustion. The C40 comes
equipped with an outside air inlet to feed combustion air
from outside the home, along with an outside air termina-
tion cap; the rigid metal duct is required but not supplied.
Consideration should be given to these factors before
deciding on a location.
E
F
Model #
in.
C40 (dimensions for
fi nished walls)
mm
Figure 2.2
Fireplace Locations
Heatilator • C40 Constitution • 480-2340 Installation Manual • Rev B 01-29-13
D
Across a corner
A
C
24 in.
(610mm)
As a
H
room
A
divider
48 in.
(1219mm)
B
G
A
B
C
41-7/8
16
89-1/2
1063
406
2273
NOTICE: In addition to these framing dimensions, also
reference the following section:
• Clearances (Section 3).
NOTICE:
• Illustrations and photos refl ect typical installations and
are FOR DESIGN PURPOSES ONLY.
Illustrations/diagrams are not drawn to scale.
Actual installation/appearance may vary due to individual
design preference.
Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
A minimum 1 in. air clearance at the back and a
minimum 1 in. air clearance to the sides of the
fi replace assembly must be maintained.
Chimney sections at any level require a 2 in. mini-
mum air space clearance between the framing
and chimney sections.
A
In an exterior chase
or projecting into a
garage
Along a wall
I
A
D
E
F
63-5/16
22-7/16
44-3/4
1608
570
1137
24 in.
(610mm)
B
I
A
24 in.
B
(610mm)
24 in.
(610mm)
G
H
I
14-1/16
55-15/16
50-7/8
357
1421
1292
7