X.21 DTE OPERATION
This only has a clock to the modem from the terrestrial equipment. Configure a cable with a 15 pin `D`
male at one end (X.21 DTE) and either a 25 pin or 37 pin `D` male (not both) at the other end as follows:
Min
X.21 DTE
Req
(15 pin D male)
Name
A
DATA CIRCUIT TOWARDS MODEM (TX)
S
6
R
4
I
5
DATA CIRCUIT FROM MODEM (RX)
T
2
C
3
COMMON LINES
Sig gnd
8
Prot gnd
1
Clocking: IMPORTANT
The interface will not work as X.21 unless you set the clocking correctly! The Tx Clocking menu should
be set take the single clock from the terrestrial by selecting
be set to return Rx data in time with the single Tx Clock by also selecting
COMBINATIONS WILL WORK.
The maximum data rate is 10Mbps (over good quality twisted pair screened cable), but this rate is
reduced as the connecting cables extend beyond 10m. As an estimate, assume the maximum rate
halves as the distance doubles (ie 5Mbps to 20m, 2.5Mbps to 40m etc).
The input clock/data phase is selected automatically, reporting a `Data Marginal` warning whenever it
has to switch phase. If the modem reports Data Marginal frequently then this is not a modem fault but an
indication that you have a clocking problem external to the modem (ie changing clock/data phase, a
problem which would otherwise have caused untraceable data errors). Check the phase of the Data In
with respect to the Clock In line.
By selecting
,
either the `Sig` Valid In` line (I) switches to the inactive state. As there is no X.21 equivalent of the
RS422 `Device (DTE) Ready In` line (TR), set this to
carrier to be switched on and off by the `Sig` Valid In` line (I) by selecting
,
.
P300H
P300 Series Modem Installation and Operating Handbook
Signal
RS422
Description
Name
B
13
Clock In
TT
11
SD
Data In
`
Sig
Valid In
12
RS
9
Data Out
RD
`
10
Sig
Valid Out
RR
Signal Ground
SG
`
Shield / Prot
PG
ground
,
it is possible to configure the modem to raise an alarm if
Circuit
25 pin
Number
A
B
A
113
24
11
17
103
2
14
4
105
4
19
7
104
3
16
6
109
8
10
13
102
7
19, 20, 21
101
1
The Rx Clock menu should also
. It is also possible to configure the Tx
37 pin
Electrical
Levels
B
35
RS422
22
RS422
25
RS422
24
RS422
31
RS422
Ground
1
Screen
. NO OTHER
,
,
,
Page 177