When YES is pressed with a non-zero value for the Autolog period, the following screen is accessed:
Log Autolog, Measurements Menu (1)
This screen allows the operator to toggle each of the first three loggable events on and off. (N) indicates
No, the data will not be logged, (Y) indicates Yes the data will be logged. Pressing the key
corresponding to each data type toggles between (Y) and (N). More options are available on subsequent
screens:
Log Autolog, Measurements Menu (2)
Finally, if AUPC is active (see AUPC in section 8.11 on page 156), another subsequent screen is
offered:
Log Autolog, Measurements Menu (3:AUPC)
P300H
P300 Series Modem Installation and Operating Handbook
Autolog(Y/N): 1 Buffer % (Y) 2 Eb/No (Y)
3 Rx User BER (N)
Autolog (Y/N): 1:BERT BER (N)
2:Tx Terr BER (N) 3:Rx Terr BER (N)
Autolog (Y/N): 1:AUPC Delta Power (Y)
2:Distant end Eb/No (N)
More
Back
More
Back
Page 122