INTRODUCTION
The following list is a guide for installing the IBM
System/34. No voltage adjustments are necessary while
installing the system.
• Follow the installation sequence shown in Figure 45-1
and check off each step as you do it.
• Report any problems that occur while you are
installing the system. Record these problems on the
Inst~lI~tion
Acti'!ity Doc!.!ment, Z130-00eC. (Use the
correct major, minor, and cause codes.) When
recording problems, use a separate document for
each work station and for the system unit.
• Always work safely. Observe all the safety rules
printed in the front of this manual.
• If you are installing a system with an integrated
modem, you may need either a dB meter (IBM part
453545), or a multimeter (IBM part 1749231) and a
dB adapter (IBM part 1749299) for modem
adjustments. The installation data table (Figure 45-14
for line 1, Figure 45-15 for line 2, and Figure 45-16
for MLCA) is used for installing data communications.
The customer must unpack and prepare the IBM 5250
Information Display System work stations. Unpacking
instructions are included with each work station.
Preparation instructions are in the IBM 5251 Model 1
and 11 Display Station Setup Procedure, GA21-9286, the
IBM 5252 Dual Display Station Setup Procedure,
GA21-9288, the IBM 5255 Display Station Model 1
Setup Procedure, GA09-1624, the IBM 5255 Display
Station Model 2 Setup Procedure, GA09-1627, the IBM
5256 Printer Setup Procedure, GA21-9290, and the IBM
5225 Printer Setup Procedure, GA34-0085. Get a copy
of the Work Station Network Diagram from the IBM
System/34 Installation and Modification Reference
Manual: Program Products and Physical Setup,
SC21-7689~
Have the customer fill out this form while
you continue the installation if he has not already done
so. If the system that you are installing has any data
communications features, fill out the installation data
table (Figure 45-14 for line 1, Figure 45-15 for line 2,
and Figure 45-16 for MLCA). It is important that you do
this because the MAPs contain references to this table.
The table will also aid you in answering configuration
questions and installing data communications features.
The following signal cables are supplied with the
System/34 to attach 5250 work stations to the system:
• One twinaxial cable (IBM part 4236482) is supplied
for the display station that will be used as the system
console.
• One twinaxial cable (IBM part 4236482) is supplied
when an IBM 5225 or 5256 Printer will be used as
the system printer.
Nut€:; A 5256 printer can be used as the system printer
only when an IBM 5211 Printer is not installed on the
system.
The customer must supply the twinaxial cables for all
other work stations that will be attached to the system.
In order to perform the System/34 system tests
(paragraph 45-600), you will need to use the system
console and the system printer. Before you run these
tests, the customer preparation procedure that does not
need an operational System/34 should be completed for
the display station that will be the system console and
for the 5256 Printer that will be the system printer.