Usb Power Select - DFI LR102 SERIES User Manual

Lr102 series system board
Table of Contents

Advertisement

2
Hardware Installation

USB Power Select

USB 0-1 power
USB 2-5 power
JP7 (for USB 0-1), JP8 (for USB 2-5) and JP10 (for USB 6-7) are used to select
the power of the USB ports. Selecting 5V_standby will allow you to use a USB
device to wake up the system.
BIOS Setting
"USB Device Wakeup From S3/S4" in the Advanced menu ("ACPI Configuration"
submenu) of the BIOS must be set to Enabled. Refer to chapter 3 for more infor-
mation.
Important:
If you are using the Wake-On-USB Keyboard/Mouse function for 2 USB
ports, the +5V_standby power source of your power supply must sup-
port ≥0.5A. For 3 or more USB ports, the +5V_standby power source of
your power supply must support ≥1A.
22
3
2
1
2-3 On:
5V_standby
3
2
1
1-2 On: 5V
(default)
select (JP7)
select (JP8)
USB 6-7 power
select (JP10)
1
2
3
2-3 On:
1-2 On: 5V
5V_standby
(default)
1
2
3