Flashing Power LED but no connection?
There's no need to worry if the Power LED blinks red and you can no
longer connect to the WAN. This simply indicates that a preset time or
connect-charge limit has been reached. There are three methods
available for unlocking:
Reset connect charge protection.
Increase the limit that has been reached.
Completely deactivate the lock that has been triggered (set limit
to '0').
If a time or connect charge limit has been reached, you will be notified in LANmonitor. To
reset the connect charge protection, select Reset Charge and Time Limits in the context
menu (right mouse click). You can configure the connect charge settings in LANconfig under
Management
Costs (you will only be able to access this configuration if 'Complete con-
figuration display' is selected under View
You will find the connect charge protection reset in WEBconfig and all parameters under
Expert Configuration
·
Online
The online LED displays the general status of all WAN interfaces:
Off
Green
Green
Green
Red
»
ADSL status
Information on connection status at the ADSL connector:
( LANCOM
821+ and
Off
LANCOM
1721+ VPN
Green
only)
Green
Red
Red
Red/
orange
LANCOM 821+ – LANCOM 1711+ VPN – LANCOM 1721+ VPN
Options...).
Setup
Charges- module.
No active connection
Flashing
Opening the first connection
Inverse flashing
Opening an additional connection
On (perma-
At least one connection is established
nently)
On (perma-
Error establishing the last connection
nently)
Interface deactivated
Blinking/flashing
Handshake/training
Permanently
Synchronization successful
Flickering
Error (CRC error, framing error, etc.)
On (permanently)
No synchronization, searching for remote station
Blinking
Hardware error
Chapter 2: Installation
Signal for reached time
or connect-charge
limit
17
Need help?
Do you have a question about the 1711+ VPN and is the answer not in the manual?
Questions and answers