Site Requirements

Space
• Counter able to support 150 lbs. (68 kg)
• Minimal clearance is required between the machines side and the wall or another appliance
• Minimum clearance of 4" behind machine
• Minimum clearance of 8" above machine
• JDF-2S approx. dimensions (H 33 x W 10 x D 25.5)
• JDF-4S approx. dimensions (H 33 x W 16 x D 25.5)
Plumbing
• 3/8" flare water connection
• Water supply must be capable of producing 3 fluid oz. a sec
• A shut-off valve should be installed in the line before the machine
• Connected to cold water
• Water pressure 20-100psi, set to 50psi if regulator is needed
Electrical
• 115VAC/208VAC
• Dedicated 20AMP Circuit with proper breaker and receptacle
• Receptacle within 5 feet of machine

Prepping Machine for Install

Step 1: Verify that all of the site requirements have been met.
Step 2: Unbox the machine and all the parts.
Step 3: Place the machine in the desired location on the counter.
Step 4: Document the complete serial number of the machine.

Install Outer Door Cover

Step 1: Connect the ribbon cables from the door cover to the control board. When connecting the ribbon cables
ensure that the number on the cable is at the top of the ribbon. For models without the portion control option
you will only need to connect the door and the door cover with a molex connector.
Step 2: Place door cover over the door.
Step 3: Secure the door cover to the door using the five screws provided.

Water Supply Install

Step 1: Flush water lines.
Step 2: Attach to the fitting at the rear of the machine.
Step 3: Turn on water and check for any kinks or leaks in the line.

Install the Air Filter

Step 1: Locate the filter and the Velcro strips supplied.
Step 2: Place Velcro strips on the filter and on the coils at the rear of the machine.
Step 3: Secure the filter to the machine using the Velcro.
After you have install the air filter verify that the refrigeration switch is in the off position.