Menu Items Test Functions / Test Program Sewing Sequence; Menu Item Stop; Menu Item Reference Start - DURKOPP ADLER 580 Operating Instructions Manual

Single-chainstitch automat for stitched eyelets
Hide thumbs Also See for 580:
Table of Contents

Advertisement

29.7 Menu item test functions / Test program sewing sequence
29.7.1

Menu item stop

29.7.2

Menu item reference start

In this menu item the sewing sequence is stopped at various steps.
This facilitates the testing and adjusting of the automate.
The following is the meaning values set:
Caution Risk of injury !
The testing program serves only for the checking of cycles and
functions. Maintenance and setting work should not be conducted
when running the testing program.
0= normal sewing cycle, the testing program is turned off.
1= the sewing cycle is stopped after switching the valves of the
thread catcher on.
2= the sewing cycle is stopped after switching the valve of the
respective thread trimming system on.
3= the sewing cycle is stopped after switching each valve on.
In this menu item it is possible to start a reference run.
This testing program is particularly helpful for the setting of the sewing
machine.
Caution: Danger of injury !
Exercise utmost caution when making the output test with
the machine running.
3
103

Hide quick links:

Advertisement

Table of Contents
loading