Function 15: System Timing Parameters; Function 16: System Feature Parameters - ESI IVX C-Class Installation Manual

With integrated answering machine
Hide thumbs Also See for IVX C-Class:
Table of Contents

Advertisement

IVX C-Class Installation Manual

Function 15: System timing parameters

Function 151: Flash hook duration
This sets the time (in seconds) that a flash hook will be sent on the current line to the Telco. The
default setting of 1.5 will cause disconnect and fresh dial tone from the CO.
Range: 0.2–2.0.
Default: 1.5.
Function 152: Transfer forward timer
This sets the number of times a transferred call will ring before following the day/night routing for the
extension or department.
Range: 1–9 rings. Default: 3.
Function 153: Hold recall timer
This is the amount of time in seconds that a call will remain on hold or park before recalling to the
extension that initiated the exclusive hold.
Range: 5–960 seconds.
Default: 60.

Function 16: System feature parameters

Function 162: Connect tone
This sets whether the system plays a system connect tone (two short beeps a user hears when a
station answers).
Default: Enabled (the beep plays).