Hardware overview/installation
IVX C-Class Installation Manual

Hardware installation

Site location
As with most electronic equipment, the environmental considerations for this site need to observe good
common sense. Provide a dry, clean, and accessible area.
Locate space in the telephone equipment room, which will provide easy connection to the 66 blocks and
110VAC power. The location should be no further than 1,000 feet from the farthest station.
0
0
Ambient room temperature must be 40
–80
(F.), and relative humidity no higher than 90%.
Note: Do not place the equipment or station cabling runs near high voltage electrical equipment or electrical
lines susceptible to high voltage surges from air conditioner compressors, etc.
The system and supporting components should be mounted to a half-inch (or thicker) plywood backboard.
IVX C-Class typical installation
B.4