Focal Point Centrurion 30 Installation, Servecing And User Instructions

Flueless inset gas fire

Advertisement

Quick Links

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Centrurion 30 and is the answer not in the manual?

Questions and answers

Summary of Contents for Focal Point Centrurion 30

  • Page 2 I I N N S S T T A A L L L L A A T T I I O O N N I I N N S S T T R R U U C C T T I I O O N N S S P P r r e e l l i i m m i i n n a a r r y y N N o o t t e e s s B B e e f f o o r r e e I I n n s s t t a a l l l l a a t t i i o o n n This is a High Efficiency, Flueless, Inset Live Fuel Effect appliance.
  • Page 3: Table Of Contents

    S S e e c c t t i i o o n n C C o o n n t t e e n n t t s s P P a a g g e e N N o o . . S S e e c c t t i i o o n n C C o o n n t t e e n n t t s s P P a a g g e e N N o o .
  • Page 4: A A P P P P L L I I A A N N C C E E D D A A T T A

    2 2 . . 0 0 A A P P P P L L I I A A N N C C E E D D A A T T A A Gas Group G20 Natural Gas CAT I2H Inlet Pressure 20 mbar Max Energy Input Gross...
  • Page 5 4 4 . . 0 0 S S I I T T E E R R E E Q Q U U I I R R E E M M E E N N T T S S ( ( c c o o n n t t i i n n u u e e d d ) ) Opening D D E E P P T T H H must be 145 mm or greater.
  • Page 6: U U N N P P A A C C K K I I N N G G T T H H E E A A P P P P L L I I A A N N C C E

    5 5 . . 0 0 U U N N P P A A C C K K I I N N G G T T H H E E A A P P P P L L I I A A N N C C E E Stand the carton the right way up, cut the strapping bands and remove the top endcap.
  • Page 7: Installation Method

    6 6 . . 2 2 G G A A S S S S U U P P P P L L Y Y R R O O U U T T E E S S The gas supply may enter the fire over the hearth or by concealed connection behind the fire.
  • Page 8 6 6 . . 4 4 I I N N S S T T A A L L L L A A T T I I O O N N M M E E T T H H O O D D 2 2 ( ( r r e e c c e e s s s s i i n n g g i i n n t t o o a a n n o o n n - - c c o o m m b b u u s s t t i i b b l l e e w w a a l l l l ) ) T T h h i i s s m m e e t t h h o o d d a a l l l l o o w w s s f f o o r r i i n n s s t t a a l l l l a a t t i i o o n n o o f f t t h h e e a a p p p p l l i i a a n n c c e e w w i i t t h h t t h h e e r r e e a a r r p p a a r r t t r r e e c c e e s s s s e e d d i i n n t t o o t t h h e e i i n n n n e e r r l l e e a a f f o o f f a a c c a a v v i i t t y y w w a a l l l l .
  • Page 9 6 6 . . 5 5 I I N N S S T T A A L L L L A A T T I I O O N N M M E E T T H H O O D D 3 3 ( ( t t i i m m b b e e r r f f r r a a m m e e d d b b u u i i l l d d i i n n g g s s ) ) Where removal of any part of a timber frame is undertaken the structural integrity of the wall must be retained.
  • Page 10 6 6 . . 5 5 I I N N S S T T A A L L L L A A T T I I O O N N M M E E T T H H O O D D 3 3 ( ( c c o o n n t t i i n n u u e e d d ) ) Rockwool to Insulate Cavity Superlux Box: 12mm thick, Fireplace Backpanel,...
  • Page 11: F F U U E E L L B B E E D D L L A A Y Y O O U U T

    8 8 . . 1 1 C C A A B B L L E E F F I I X X I I N N G G When using this method for fixing, the minimum depth of the open- ing must be increased from 145 mm to 175 mm.
  • Page 12 9 9 . . 0 0 F F U U E E L L B B E E D D L L A A Y Y O O U U T T ( ( c c o o n n t t i i n n u u e e d d ) ) Place the centre row of four broken coals, making sure that they do not fall down into the flame port but bridge across the spaces as shown.
  • Page 13: T T E E S S T T I I N N G G A A N N D D C C O O M M M M I I S S S S I I O O N N I I N N G

    1 1 0 0 . . 0 0 F F I I T T T T I I N N G G T T H H E E D D E E C C O O R R A A T T I I V V E E F F R R A A M M E E A A N N D D H H O O O O D D The appliance is supplied with a decorative frame and hood.
  • Page 14: B B R R I I E E F F I I N N G G T T H H E E C C U U S S T T O O M M E E R

    1 1 1 1 . . 2 2 S S P P A A R R K K F F A A I I L L U U R R E E The gap between the spark electrode and the pilot should be 3 - 5mm to produce a good spark. There should be no need to adjust this.
  • Page 15: S S E E R R V V I I C C I I N N G

    1 1 3 3 . . 0 0 S S E E R R V V I I C C I I N N G G ( ( c c o o n n t t i i n n u u e e d d ) ) 10.
  • Page 16 1 1 3 3 . . 4 4 C C A A T T A A L L Y Y S S T T It is recommended that the catalyst is inspected for signs of damage and dirt during routine servicing proce- dures.
  • Page 17: T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G G G U U I I D D E

    1 1 4 4 . . 0 0 T T R R O O U U B B L L E E S S H H O O O O T T I I N N G G G G U U I I D D E E F F i i r r e e s s p p a a r r k k s s b b u u t t p p i i l l o o t t d d o o e e s s n n o o t t l l i i g g h h t t No gas to fire - check isolators are open.
  • Page 18 U U S S E E R R I I N N S S T T R R U U C C T T I I O O N N S S S S e e c c t t i i o o n n C C o o n n t t e e n n t t P P a a g g e e N N o o Important Notes...
  • Page 19 2 2 . . 0 0 F F I I R R E E F F R R O O N N T T This fire is supplied with a particular style of fire front. Use of the fire front will ensure an adequate airflow under the firebox for the correct functioning of this appliance.
  • Page 20 5 5 . . 0 0 O O P P E E R R A A T T I I N N G G I I N N S S T T R R U U C C T T I I O O N N S S ( ( c c o o n n t t i i n n u u e e d d ) ) Upon lighting and after the further 10 seconds, release the knob and turn further to the left to the ON posi- tion.
  • Page 21 1 1 0 0 . . 0 0 L L I I S S T T O O F F S S P P A A R R E E P P A A R R T T S S P P A A R R T T N N O O .

Table of Contents