ALT KEY

CLR & SOLO CLR KEYS – see also CLEAR
1. CLR key: used to reset channels, buses or groups of
2. SOLO CLR: Pressing this key when lit will clear all active PFL or AFL selections.
24
ALT is a modifier key used by the following functions:
CLR (CLeaR function)
CUE CONTROL
MIXING to AUX BUSES
MIXING to MATRIX BUSES
Refer to these sections for detail on the operation and use.
parameters to their factory defaults as follows:
CLR + channel or bus SELect will reset all audio
parameters within that channel or bus. to the factory
defaults.
CLR + function key within the ACS (such as EQ, GATE
or COMP) will reset all assocaited parameters of the
selected channel or bus to the factory defaults.
CLR + GEQ HI or LO will reset all bands in an active
GEQ to 0dB
CLR+ MUTE 'n' will clear all channel or bus assignments to Mute Group 'n'
CLR+ tOTEM follow key will reset all contributions and ON status from channels or buses to
the BUS/MTX/FX'n' back to the factory defaults.
NOTE: The reset refers only to the main audio parameters and does not affect functions
such as SOLO, bus type, names patching and mute assignment.
CAUTION: ALT+ CLR+ function key within the ACS (such as EQ, GATE or COMP) will reset
all associated parameters on all channels to the factory defaults.