GEQ

The Si Compact features a 28 band Graphic EQ on every bus on each and every Aux, Matrix, and
Master Bus; having a GEQ on every bus means there is no need to 'patch' the GEQ, just enable
it when required with no risk of running out of DSP!
The GEQ function is available when in BUS or MTX mode, when the LR or MONO master is SELected
or when FOLLOWing a bus, at all other times the GEQ keys will have no function.
NOTE: Whilst in BUS or MTX modes it is possible to swap between the GEQ on different buses
with the GEQ open by pressing another SELect key.
NOTE: To BYPASS the GEQ press both the GEQ HI and LO keys together and both GEQ keys
will light, to exit BYPASS press either one of the GEQ keys.
NOTE: To easily reset any band back to 0dB press the associated lit red ON key.
NOTE: To reset all bands of the active GEQ press CLR together with either of the GEQ keys.
Soundcraft Si Compact User Guide 1211
1. Press either the GEQ HI or LO keys to open the GEQ across the 14 faders immediately
left of the FADER BANK keys.
2. Toggle between GEQ HI & LO with the appropriate key. The frequency bands for HI and
LO are printed above each fader whilst the scale on the left hand side of the fader slot
indicates the dB of cut or boost applied. The 'Function Focus' display on the LCD can be
used for an exact indication of the band gain.
3. To exit the GEQ press the lit GEQ HI{LO} key, any of the FOLLOW keys or INA, INB, BUS or
MTX keys.