7-7
Measuring with the peak voltage adapter 584.29.042.000: static generator values
Measuring conditions:
– cold engine
– seat and tank removed
– all connectors and the ground connection in a non-corroding condition, connectors tightly connected
– battery loaded (if installed) and light switch turned off
– compression release lever pulled
– kick the kick starter forcefully at least 5 times for each measurement
1
2 S
Check the generator output
colors:
– between yellow and brown (ground), connector
Multimeter display: 15 volts +/- 1 volt
– take the same measurement with connector
Multimeter display: 12 volts +/- 1 volt
– between white and brown (ground), connector
Multimeter display: 19 volts +/- 1 volt
– take the same measurement with connector
Multimeter display: 14 volts +/- 1 volt
NOTE: The black measuring lead
be applied to the ground.
for voltage between the following cable
6
disconnected
1
connected
1
disconnected
2
connected
2
of the peak voltage adapter must
S