A
0 Ω
B
Checking the starter
– Disconnect the negative terminal from the battery and remove the
– Connect the negative terminal from a 12V battery to the starter case
– The starter should start to turn when the electric circuit is closed.
– If not, replace the starter.
Checking the start relay
2
– Remove the seat and the filter box cover.
– Disconnect the negative terminal from the battery.
– Remove the starter relay from the support.
– Pull the connector
– Disconnect cables
4
– Connect the starter relay to a 12 V battery as illustrated.
– Use an ohmmeter to check the continuity between terminals
NOTE: you should hear a click when you switch the starter relay.
The starter relay is mounted in the reverse order, paying attention to
the following points:
– Replace any damaged or defective parts.
Dismounting and mounting the battery
– Remove the seat.
– First disconnect the negative terminal, then the positive terminal
– Remove the filter box cover, detach the rubber strap
The battery is mounted in the reverse order, paying attention to the
following points:
– Replace any damaged or defective parts.
5
– Connect the positive terminal then the negative terminal to the
Charging the battery
– D
– T
– I
– I
– Q
– Connect KTM battery charger no. 584.29.074.000. The battery
– If it is not used for longer periods of time, recharge the battery every
starter.
and briefly connect the positive terminal from the battery to
connector
on the starter (use thick cables).
1
from the starter relay.
2
and
3
4
starter relay.
.
B
Setpoint value: 0 Ω OK
Setpoint value: ∞ Ω defective
from the battery.
the battery.
battery.
!
CAUTION
O NOT REMOVE THE LOCKING STRIPS
,
O LOAD
CONNECT THE BATTERY TO THE BATTERY CHARGER BEFORE YOU
SWITCH ON THE BATTERY CHARGER
F YOU ARE CHARGING THE BATTERY IN A CLOSED ROOM
. T
VENTILATED
HE BATTERY PRODUCES EXPLOSIVE GASSES WHILE CHARGING
F THE BATTERY IS CHARGED TOO LONG OR AT AN EXCESSIVE VOLTAGE
LEAK THROUGH THE SAFETY VALVES AND THE BATTERY WILL LOSE CAPACITY
UICK CHARGES WITH HIGH VOLTAGE WILL IMPAIR THE SERVICE LIFE OF YOUR BATTERY
charger can also be used to test the offload voltage, the battery's
startability and the generator capacity. This battery charger cannot be
overcharged.
3 months.
from the starter relay and remove the
and remove
5
!
.
.
,
MAKE SURE IT IS WELL
7-4
and
A
.
,
ACID WILL
.
.