Measuring with the peak voltage adapter 584.29.042.000: static ignition values
Measuring conditions:
– cold engine
– seat and tank removed
– all plug and socket connectors and the ground connection in a non-corroding condition, plugs tightly connected
– depress the kickstarter forcefully at least 5 times for each measurement
2
4
6
R
3
1
5
S
7
Connecting the peak voltage adapter and setting the multimeter
The peak voltage adapter is equipped with 4 cables: 2 red and 2 black.
One red and one black cable have a measuring tip which - to measure -
is applied to the electric terminals of the components. The two other
cables have plugs that are plugged into the respective sockets on the
multimeter. The red plug is plugged into the socket on the multimeter
marked with a +, V or a red circle
The black plug must be plugged into the socket marked with a -, Com
or a black circle
.
2
Turn the multimeter on and switch to the range for voltage
measurements - DCV.
multimeters must be set to the level of voltage to be measured
!
T
HE PEAK VOLTAGE ADAPTER IS NOT SUITABLE TO MEASURE SECONDARY VOLTAGES
(
-
THE HIGH
VOLTAGE SIDE OF THE IGNITION COIL
0
. 500
BETWEEN
AND APPROX
T
O PREVENT AN ELECTRIC SHOCK
THE CONNECTING CABLE WITH YOUR BARE HANDS DURING OR IMMEDIATELY AFTER
.
MEASURING
Check the pulse generator (pick up) for an output signal - two-pole plug
with green and red cables:
4
– Apply the red measuring tip of the peak voltage adapter
584.29.042.000 to the green cable and the black measuring tip to
the red cable, disconnect plug
Multimeter display: 4.5 volts +/- 0.5 volt
– Same measurement with CDI unit connected.
Multimeter display: 3 volts +/- 0.5 volt
Check the generator charging coil for ignition capacitor charge - two-
pole plug
with black/red and red/white cables:
5
– Apply the red measuring tip of the peak voltage adapter to the
black/red cable and the black measuring tip to the red/white cable,
disconnect plug
to disconnect the CDI unit.
5
Multimeter display: 30 volts +/- 5 volts
– Same measurement with CDI unit connected
Multimeter display: 200 volts +/- 10 volts
Check the primary voltage output
voltage (blue/white cable):
– Apply the red measuring tip
black/white cable (ground) and the black measuring tip
blue/white cable, CDI unit and ignition coil
Multimeter display: 200 volts +/- 10 volts
.
1
Depending on the measurement, some
CAUTION
). T
HE MEASURING RANGE IS
.
VOLTS
WARNING
,
DO NOT TOUCH METAL PARTS OR THE ENDS OF
to disconnect the CDI unit.
4
for ignition coil control for output
6
of the peak voltage adapter to the
R
connected.
7
7-6
.
3
!
to the
S