Check Code List - Toshiba MMK-AP0072H Service Manual

Hide thumbs Also See for MMK-AP0072H:
Table of Contents

Advertisement

7-2. Check Method
On the remote controller (Main remote controller, Central control remote controller) and the interface P .C. board
of the outdoor unit, a check display LCD (Remote controller) or 7-segment display (on the outdoor interface P .C.
board) to display the operation is provided. Therefore the operation status can be known. Using this self-diagno-
sis function, a trouble or position with trouble of the air conditioner can be found as shown in the table below.

7-2-1. Check Code List

The following list shows each check code. Find the check contents from the list according to part to be checked.
• In case of check from indoor remote controller: See "Main remote controller display" in the list.
• In case of check from outdoor unit: See "Outdoor 7-segment display" in the list.
• In case of check from AI-NET central control remote controller: See "AI-NET central control display" in the list.
• However connection with AI-NET central control is disabled for the wall type (2 series).
• In case of check from indoor unit with wireless remote controller: See "Sensor block display of receiving unit"
in the list.
Check code
Outdoor 7-segment display
Main remote
controller
display
Sub code
E01
E02
E03
E04
No. of indoor units in which sensor
E06
E06
has been normally received
E07
E08
E08 Duplicated indoor addresses
E09
01: Indoor/Outdoor communication
E12
E12 02: Communication between
outdoor units
E15
E15
00: Capacity over
E16
E16
01: No. of connected units
E18
00: No header unit
E19
E19
02: Two or more header units
01: Outdoor of other line connected
E20
E20
02: Indoor of other line connected
E23
E23
E25
E25
No. of outdoor units which
E26
E26
received signal normally
E28
E28 Detected outdoor unit number
01: IPDU1 error
02: IPDU2 error
03: IPDU1, 2 error
E31
E31 04: Fan IPDU error
05: IPDU + Fan IPDU error
06: IPDU2 + Fan IPDU error
07: All IPDU error
IPDU: Intelligent Power Drive Unit
¡ : Lighting,
ALT.: Flashing is alternately when there are two flashing LED.
SIM: Simultaneous flashing when there are two flashing LED
AI-NET central
control display
97
04
04
96
99
42
42
89
97, 99
96
42
15
15
15
d2
CF
¤
: Flashing,
Wireless remote controller
Sensor block display
of receiving unit
Ready Timer
Flash
Operation
Communication error between indoor and
l
l
¤
remote controller
(Detected at remote controller side)
l
l
¤
Sending error of remote controller
l
l
Communication error between indoor and
¤
remote controller (Detected at indoor side)
l
l
Communication circuit error between indoor
¤
and outdoor (Detected at indoor side)
l
l
¤
Decrease of No. of indoor units
l
l
Communication circuit error of indoor and
¤
outdoor (Detected at outdoor side)
l
l
¤
Duplicated indoor addresses
l
l
¤
Duplicated master remote controllers
l
l
¤
Automatic address start error
l
l
¤
No indoor automatic address
l
l
¤
No. of connected indoor units / Capacity over
l
l
Communication error between indoor header
¤
and follower units
l
l
¤
Outdoor header units quantity error
l
l
Other line connected during automatic
¤
address
l
l
Sending error in communication between
¤
outdoor units
l
l
¤
Duplicated follower outdoor addresses
l
l
¤
Decrease of No. of connected outdoor units
l
l
¤
Follower outdoor error
l
l
¤
IPDU communication error
38
FILE NO. SVM-05052
l
: Goes off
Check code name
Judging
device
Remote
controller
Remote
controller
Indoor
Indoor
I/F
I/F
Indoor /
I/F
Remote
controller
I/F
I/F
I/F
Indoor
I/F
I/F
I/F
I/F
I/F
I/F
I/F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmk-ap0122hMmk-ap0092h

Table of Contents