No.
Part name
X
Cross-flow fan
6) Slide the fan motor rightward to remove it.
7) Take off fixing screws (2 pcs.) from fixing
8) Lift up the left side of the heat exchanger
<Caution to reassembling>
a) When assembling the bearing base, check
b) When assembling the fan motor, remove
c) When attaching motor band (Right),
Procedure
support at right side of the heat ex-
changer.
toward you, and then remove the cross-
flow fan.
the drain pipe is surely incorporated to the
rear plate.
(Otherwise water leak may be caused.)
fan motor rubber (shaft center side),
mount it in the position in the following
figure, and then mount the fan motor.
• Mount the cross-flow fan so that the right
end of joint which is first one from right
of the cross-flow fan is set at position
70.5mm apart from wall of the rear side
of the main unit.
• Mount the cross-flow fan so that D-cut
part at the center comes to the mounting
hole of set screw.
• Determine the position of fan motor as
shown in the figure for mounting.
W
(Perform work of item
perform work of item b), set the hooking
claws (2 positions) of the motor band
(Right) in the main unit, and then perform
reverse procedure of item 6).
.)
117
FILE NO. SVM-05052
Remarks
Joint
Cross-flow fan
Central D-cut part
Motor band
Hooking claws
(Right)
(2 positions)