Installation and Operation, cont'd
Cabling
For each control module to be connected to an MLC, set the rear
panel DIP switches, then follow these steps:
1.
If it wasn't already done when the wall box was installed,
cut a length of Extron Comm-Link cable to go between the
MLC and the control module.
2.
Using the following diagram as a guide, attach a 3.5 mm,
5-pole captive screw connector to the end of the cable that
will be plugged into the control module, and connect wires
on the other end of the cable to the MLC's IR/RCM port (a
4-pole direct insertion captive screw connector).
Wire both ends of the cable identically (pin A to pin A, pin
B to pin B, etc.).
A
+12VDC
B
Ground ( )
C
Control signal (IRCM)
MLC
IR / RCM
port
A B C D
IR / RCM
MLC to a control module
Only three wires are required, but you can use four wires (A,
B, C, D) if an IR Link infrared repeater will be daisy chained
with the control modules. Refer to the IR Link User's
Manual for details.
Connectors are included with each control module, but the
cable must be purchased separately. See the illustration on
the next page for reference, and see appendix A for cable
part numbers and conductor gauges.
3.
Plug the 5-pole connector into either one of the control
module's communications connectors.
IRCM-DV+ • Installation and Operation
2-4
Total
distance
A B C D E
Control
from MLC:
Module
connector
150' (45.7 m)
max.
Control
Module(s)
DVD & VCR CONTROL
Tx
DVD
VCR
TITLE
MENU
TUNER
ENTER
TV/VCR
A
PREV/REW
PLAY NEXT/FWD PAUSE
STOP
B
C
DISPLAY
POWER
VCR
DVD
Laptop
VOLUME
MAX/
MIN
Extron
MLC 206
MLC 206
MediaLink Controller
A B C D
IR / RCM
MLC to a daisy chain of control modules
A
B C
D
A
B
C
Control Module
A
B C
D
E
A
B C
D
E
A
+12VDC
A
B
Ground ( )
B
C
Control signal (IRCM)
C
MLC
IR / RCM
port
4.
Cut a cable and attach 5-pole connectors to both ends of it
for each additional control module that will be connected
in a daisy chain. Wire both ends of the cable identically
(pin A to pin A, pin B to pin B, etc.). One IRCM-DV+ and
up to two other control modules in any combination of
other models (IRCM, ACM, RCM) can be daisy chained
together and connected to the MLC.
5.
Plug one end of the cable into the control module's
remaining communications connector, and plug the other
end into a communications connector on the next control
module. The following photo shows control modules
connected to an MLC in a typical daisy chain setup.
IRCM-DV+ • Installation and Operation
E
A
B C
D
E
Control Module
Total
distance
from MLC:
150' (45.7 m)
max.
DVD & VCR CONTROL
Tx
DVD
VCR
TITLE
MENU
TUNER
ENTER
TV/VCR
PREV/REW
PLAY NEXT/FWD PAUSE
STOP
Control
Module
ROOM CONTROL
SCREEN POSITION
LIGHTING
ON / OFF
Control
Module
DISPLAY
POWER
VCR
DVD
Laptop
VOLUME
MAX/
MIN
Extron
MLC 206
MediaLink Controller
MLC 206
2-5
Need help?
Do you have a question about the IRCM-DVplus and is the answer not in the manual?
Questions and answers