Dexter Laundry 75LB CAPACITY COMPUTER CONTROL OPL WASHER Owner's Booklet page 10

75lb capacity computer control opl washer
Table of Contents

Advertisement

5.
Each bath can be programmed with the following options. Use the "DOWN" and "UP" keys
to select the desired setting and the "START" key to move to the next option.
DISPLAY
FUNCTION
Ct **
Tumble Time
t
**
Water Temperature
L **
Water Level
dF *
Type of Fill
S **
Spin Time
IS *
Injection Source
1
A delayed fill will pause the time count until the selected level is reached. A timed fill will
allow the time count to continue until the selected level is reached.
2
Codes for injections sources are defined at the end of the programming section. When the
No Water bath is selected, the electronic controller prohibits injection signals. The
programmed injection source value is ignored.
To exit the programming of a bath, press the "STOP" button once and use the "UP" and
"DOWN" keys select another bath. Press the "STOP" button again to select a different cycle to
change. To end programming, turn the key to "RUN" position
Note: The Wash Cycle programming mode will automatically exit and return to
the Idle mode if no buttons are pushed for one minute.
WASH CYCLE PARAMETER RANGES
The range of each cycle parameter is shown below:
Cycle Time
Water Temperature
Water Level
Delay Fill
Spin Time
Injection Source
OPTIONS
Two-digit amount of time in minutes.
HH for hot, CH for warm, CC for cold
and EE for no water.
Lo for low, Hl for high.
d for delayed fill, t for timed fill.
Two-digit amount of time in minutes.
Single digit code indicating injector signal(s).
0 to 15 minutes for Prewash, Wash, Rinse1, 2, 3 and 4
1 to 15 minutes for Final Rinse
For the bathes that can, if the time is set to zero, then the
bath will be eliminated from the cycle.
HH – hot, CH – warm, CC – cold, EE – no water
HI – high, LO – low
The selections are "d" for delay the bath time until water
level is reached or "t" to count down bath time during the
fill.
0 to 10 minutes for Prewash, Wash, Rinse, 2, 3 and 4
1 to 10 minutes for Final Spin
0 to 6
1
2
11