Download Print this page

Dometic CC 05 Operating And Installation Instructions page 7

Glass ceramic gas cooktop

Advertisement

If the gas tap becomes sluggish or jammed, then it must either be replaced or the affected
tap removed from the chamber, cleaned in benzine and lubricated with a special gas tap
grease, e.g. type "Staburgas no. 32" from the Klüber company in Munich. This work must
be carried out by a professional gas technician.
The pressure regulators used between the gas cylinder and the appliance must comply
with the categories in the following table:
Appliance category
I
3+
I
3B
I
3B/P
I
3B/P
IMPORTANT: THE APPLIANCE MUST BE INSTALLED BY AN AUTHORIZED
TECHNICIAN IN ACCORDANCE WITH THE APPLICABLE STANDARDS (EN
1949) REGISTERED BY CORGI (Council for Registered Gas Installers).
IMPORTANT: TO PREVENT ANY RISK OF ACCIDENT, IT IS NECESSARY
THAT THE APPLIANCE BE INSTALLED ACCORDING
INSTRUCTIONS. IMPROPER INSTALLATION WILL VOID THE WARRANTY.
ANY MODIFICATION TO THE APPLIANCE CAN RESULT IN DANGER AND
IS PROHIBITED!
2. Ventilation of the installation location
Every room where one or more appliances are to be installed must have one or more
openings to allow the entry of fresh air. Above the appliance there have to be one or
several openings in order to assure the exhaust of combustion and renewal of fresh air.
These ventilation openings must comply with the requirements of EN 1646-1, EN 1949
and EN 721.
These openings, in addition to the exhaust gas outlet and the fresh air inlet must be
checked from time to time and cleaned by the user, if necessary (e.g. in winter, snow, ice,
etc. must be removed).
For the installation of the gas appliance, the applicable regulations, in particular EN 1949
must be observed.
The distance and position of the exhaust from doors, windows and ventilation openings
must comply with EN 1949.
The minimum distance for furniture located above the appliance is 400 mm.
Particular care must be taken so that the exhaust gas line is never at a slope.
Supply pressure
28-30/37 mbar
30 mbar
28-30 mbar
30 mbar
Gas
butane/propane
butane
butane/propane
butane/propane
7
Rating of the pressure
regulator
1.5 kg/h
1.5 kg/h
1.5 kg/h
1.5 kg/h
TO THESE

Advertisement

loading