Steel City 50000 User Manual page 13

Metal band saw
Table of Contents

Advertisement

Fig.5
1. Loosen the clamping level(A)and feed the
saw band guide (B)as far as possible along
the workpiece.
2. Tighten the clamping lever(A); SEE FIG.5
Changing the cutting angle
!
Danger!
Before adjusting the power tool, always press
the main switch
Off/0.
The cutting angle can be adjusted steplessly
5 (
from
0 to 4
end stop) without interuption.
Fig.6
B
A
1. Loosen the clamping lever(A) and set the
swivel support (B) to the required cutting
angle. Use the scaling on the machine
tables as an adjustment aid.
2. Re-tighten the clamping lever. SEE FIG.6
Changing the saw band
!
Danger!
Before adjusting the power tool, always press
the main switch
plug.
!
Caution!
A
Risk of injury! Wear protective gloves!
B
1. Press the main switch Off/0 and pull out
the mains plug.
2. Loosen the clamping lever(A, in Fig.5) and
push back the saw band guide (B,
as far as the stop.
3. After loosening the 4 screws, remove the
protective housing from the saw frame.
4. Release saw belt tension by swivelling the
tension lever clockwise.
Fig.7
5. Slacken the hex-head nut (a) on both outer
saw band guides.
6. Rotate screw (b) slightly in an anti-
clockwise direction until the saw band is
C
released.
7. First take the saw band off the guide
rollers and then out of the guides.
13