Chroma Color Force 12 User Manual

Chroma Color Force 12 User Manual

Color force 12
Hide thumbs Also See for Color Force 12:

Advertisement

Chroma-Q
®
Color Force™ 12
User Manual
Version1.8 August 2014, Software Version 2.2
PN: 621-0500

Advertisement

Table of Contents
loading

Summary of Contents for Chroma Color Force 12

  • Page 1 Chroma-Q ® Color Force™ 12 User Manual Version1.8 August 2014, Software Version 2.2 PN: 621-0500...
  • Page 2 Chroma-Q unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above; (e) by modification, repair or service by anyone other than Chroma-Q, who has not applied for and been approved by Chroma-Q to do such modification, repair or service unless the Customer provides acceptable proof to Chroma-Q that the defect or damage was not caused by the above;...
  • Page 3 Chroma-Q products are safe, effective, and fully satisfactory for the intended end use. Suggestions of use shall not be taken as inducements to infringe any patent.
  • Page 4: Table Of Contents

    4. 4. 4. 4. Specification Specification ................................14 Specification Specification Technical specifications ............................15 Illuminance measurements ........................... 15 Drawings ................................16 5. 5. 5. 5. Maintenance Maintenance Maintenance Maintenance ................................16 www.chroma-q.com Color Force 12 User Manual V1.8 August 2014...
  • Page 5: Product Overview

    8m / 26ft with smooth, theatrical grade dimming. The Color Force 12 is equipped with a built-in power supply and can operate as a stand-alone unit or be remotely controlled through ANSI E1.11 USITT DMX 512-A protocol. The Color Force 12 features a total of 48 high powered LEDs.
  • Page 6: Cabling

    XLR 5-pin connectors. The chassis are ground bonded. Note: The maximum number of Color Force 12 fixtures running off a single power input cable is 10 at 120V AC or 20 at 240V AC.
  • Page 7: Control

    The Color Force 12 fixture has the ‘chevron’ markings stamped on both ends and printed at the rear enclosure to indicate the side of the fixture that should be adjacent to the wall or cyclorama. Control Color Force 12 fixture can operate as a stand-alone unit or be controlled remotely via ANSI E1.11 USITT DMX512-A protocol. The control functions can be accessed through the LCD display at the rear of the fixture with 4 push buttons.
  • Page 8 4 channels for effects (Colour Speed, Range, Step and Intensity Effects). Grouping options: grouping by individual cell “Duo” and “All” cells. A Color Force 12 fixture consists of 2 cells. Cell grouping “Duo” allows individual control of each single cell. In “All” grouping, both cells can be controlled as 1 group.
  • Page 9 • Look Store The Color Force 12 has 31 internal preset FX Looks for stand-alone operation, 1-23 are pre-programmed. To replay a Look in stand-alone operation, Press Up/Down buttons to access “Look Store”, Press Enter, press Up/Down buttons to select the desired Look and press Enter for 2 seconds to save settings.
  • Page 10 Frequency: Frequency: The Color Force 12 has four frequency settings available - 600, 1200, 2400, 4800. This allows for the LED scan rate to be synchronised with the video camera and avoid a flickering effect. Press the Up/Down buttons to select the desired frequency, Press Enter for 2 seconds to save settings.
  • Page 11 Press Enter and Up/Down to select between “Standard” or “Matching CF48/72”. Fan Speed The Color Force 12 is built with an internal fan with 4 speed options to regulate noise levels and the cooling process. “Quiet” – the fan is off •...
  • Page 12: Dmx Protocol

    DMX Protocol Color Force 12 DMX Personality Mode 1-3: Control Mode 3 Control Mode 3 Control Mode 3 Control Mode 3 Control Mode 1 Control Mode 1 Control Mode 1 Control Mode 1 Control Mode 2 Control Mode 2 Control Mode 2...
  • Page 13 9 DMX channels 9 DMX channels 5 DMX channels 5 DMX channels 5 DMX channels 5 DMX channels Color Force 12 DMX Personality Mode 7-10: Control Mode Control Mode 8 8 8 8 Control Mode 10 Control Mode 10 Control Mode...
  • Page 14 Light Cyan Full 62-64 Blue Full 65-68 Light Blue Full 69-71 3200 White 72-74 5600 White 75-78 Empty 79-81 Empty 83-85 Empty 86-88 Empty 89-91 Empty 92-94 Empty 95-97 Empty 98-100 Empty www.chroma-q.com Color Force 12 User Manual V1.8 August 2014...
  • Page 15: Thermal Performance

    Thermal Performance The Color Force 12 fixture is equipped with an internal fan to drive the internal cooling system. If the internal temperature of the Color Force 12 exceeds 75 º C the output of the fixture is reduced for automatic protection. This happens on rare and extreme conditions when ambient temperature is over 35 º...
  • Page 16: Technical Specifications

    Asymmetrical direct illumination CCT: Adjustable 1000 – 10000K Color Gamut: Performance enhanced CRI: Lamp Life: L70 up to 50,000 hours Illuminance measurements Lux and footcandle measurements with RGBA at full intensity: www.chroma-q.com Color Force 12 User Manual V1.8 August 2014...
  • Page 17: Drawings

    Drawings Maintenance With care, the Color Force 12 will require little maintenance. However, as the unit is likely to be used in a stage environment we recommend periodical internal inspection and cleaning of any resulting dust and cracked oil residue.

Table of Contents