Clearance to Combustibles

Back (from Standoffs)
Side (from standoffs)
Floor
Ceiling (from bottom of fireplace)
Top (from standoffs)
Louvered Unit
Top of 90 degree bend in Minimum
Enclosure of
37.75
to 40 inches
Enclosure over 40 inches
CVCK Unit (non louvered)
Top of 90 degree bend in Minimum
Enclosure of 40.5inches to 43 inches
Enclosure over 43inches
Top of Horizontal Pipe
Side & Bottom of Horizontal Pipe
Vertical Vent Pipe
Vertical Vent Pipe
Systems
Clearance to Combustibles
Back (from Standoffs)
Side (from standoffs)
Floor
Ceiling (from bottom of fireplace)
Top (from standoffs)
Louvered Unit
Top of 90 degree bend in Minimum
Enclosure of 42 to 46 inches
Enclosure over 46 inches
CVCK Unit (non louvered)
Top of 90 degree bend in Minimum
Enclosure of 44.5inches to 48.5 inches 5 inches/38 mm / All Vent Systems
Enclosure over 48.5inches
Top of Horizontal Pipe
Side & Bottom of Horizontal Pipe
Vertical Vent Pipe
Vertical Vent Pipe
Systems
MQZDV3318 - Clearance to Combustibles
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
60 inches/150 cm
0 inches/0 mm
3 1/4 inches/140 mm / All Vent Systems
2 1/2 inches/38mm/All Vent Systems
5 inches/38 mm / All Vent Systems
2 1/2 inches/38mm All vent Systems
1 1/2 inches/38 mm / All Vent Systems
1 inch/25.5mm / All Vent Systems
1 inch/25.5mm / Kingsman Vent Systems
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp
MQZDV3622 - Clearance to Combustibles
0 inches/0 mm
0 inches/0 mm
0 inches/0 mm
60 inches/150 cm
0 inches/0 mm
5 1/2 inches/140 mm / All Vent Systems
2 1/2 inches/38mm/All Vent Systems
2 1/2 inches/38mm All vent Systems
1 1/2 inches/38 mm / All Vent Systems
1 inch/25.5mm / All Vent Systems
1 inch/25.5mm / Kingsman Vent Systems
1 1/4 inch/32mm / Simpson/AmeriVent/Selkirk Direct Temp
(NOTE -Floor) if installing the
appliance directly on carpeting or
other combustible materials other
than wood flooring, the appliance
shall be installed on a metal or
wood panel, the full width and
depth of the appliance. Carpet
may extend 1 inch above the floor
of appliance.
For units with CVCK (Clear View
Circulating Kit) see framing with
CVCK to establish floor heights
(NOTE -Floor) if installing the
appliance directly on carpeting or
other combustible materials other
than wood flooring, the appliance
shall be installed on a metal or
wood panel, the full width and
depth of the appliance. Carpet
may extend 1 inch above the floor
of appliance.
For units with CVCK (Clear View
Circulating Kit) see framing with
CVCK to establish floor heights
16