Grounding the Device

The RSG2200 chassis ground terminal uses a #6-32 screw. It is recommended to terminate the ground
connection with a #6 ring lug and torque it to 1.7 N·m (15 lbf·in).
Figure 13: Chassis Ground Connection
1. Stainless Steel Stud
Section 2.5

Connecting to the Device

The following describes the various methods for accessing the ROS console and Web interfaces on the device.
For more detailed instructions, refer to the ROS User Guide for the RSG2200.