CHARGING PB (LEAD-ACID) BATTERY IN THE CHARGE MODE
This program is only suitable for charging Pb (lead-acid) battery with nominal voltage from
2 to 20V. Pb (lead-acid) battery is completely different from NiCd/NiMH battery. These
batteries can only deliver current lower in comparison to their capacity. The same
restriction applies to the charging process. Consequently, the optimum charge current can
only be 1/10 of the capacity. Pb battery can not be used for fast-charging, please follow the
instructions provided by the battery manufacturer.
Due to the chemistry characteristic of Pb battery, the cut off point may be difficult to detect
sometimes. We recommend user to use CAPACITY CUT OFF feature to protect the
battery. You can press START/ENTER key to make it blink and alter the value of
parameters using INC or DEC key, press START/ENTER key to store the value.

CHARGING OF THE PB BATTERY

Pb CHARGE
4.0A
12.0V(6P)
- +
- +
DEC
INC
DEC
INC
Batt type
Start
'>3 seconds'
Stop
Enter
Pb-6 4.0A 12.59V
CHG 022:43 00682
Battery
Elapsed
Battery
type
time
voltage
Charge
Charged
current
capacity
DISCHARGING OF THE PB BATTERY
Pb DISCHARGE
1.0A
12.0V(6P)
- +
- +
DEC
INC
DEC
INC
Batt type
Start
'>3 seconds'
Stop
Enter
Pb-6 4.0A 12.59V
DCS 022:43 00682
Battery
Elapsed
Battery
type
time
voltage
Discharge
Discharged
current
capacity
Set up the charge current on the left and nominal voltage on the
right. Range of current is 0.1-6.0A, the voltage should match the
battery being charged. Press START/ENTER key for more than 3
seconds to start charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press
START/ENTER key again to store the parameter value you set.
Press BATT TYPE/STOP key to end the program.
Set up the charge current on the left and nominal voltage on the
right. Range of discharge current is 0.1-1.0A, the voltage should
match the battery being charged. Press START/ENTER key for
more than 3 seconds to start charging.
The screen displays the real-time discharging status. Press
START/ENTER key to alter discharge current. Press
START/ENTER key again to store the parameter value you set.
Press BATT TYPE/STOP key to end the program.