VOLTAGE BALANCING AND MONITORING IN THE DISCHARGE PROCESS
The processor monitors voltage of each cell when the battery packs are during its 'storage'
and 'discharging' process. If voltage of any cell is abnormal, SKYRC QUATTRO B6AC will
show error message and terminate the program forcibly. So if there is battery damage or
disconnection, you can see the error message and press INC to know which cell is
damaged.

DISCHARGING OF LITHIUM BATTERY

LiPo DISCHARGE
1.0A 11.1V(3S)
- +
- +
DEC
INC
DEC
INC
Batt type
Start
'>3 seconds'
Stop
Enter
Li3s 0.4A 12.59V
DSC 022:43 00682
Number
Elapsed
Battery
of cells
time
voltage
Discharge current
Discharged capacity
BATTERY VOL ERR
CELL LOW VOL
INC
4.14 4.16 4.09
2.18 0.00 0.00
CHARGING NICD/NIMH BATTERY IN THE CHARGE MODE
This program charge the battery using the current you set up. In the 'auto' state, you
should set up the upper limit of the charge current to avoid damage by excessive feeding
current. Some batteries of low resistance and capacity can lead to higher current in the
'auto' charging mode. But in the manual mode, it will charge with the current you set. You
can make it blink in the current field and press INC and DEC simultaneously to swap
between Auto and Manual Mode. NOTE: Allowable fast charge current: 1C-2C.
CHARGING OF NICD/NIMH BATTERY
NIMH CHARGE Aut
CUR LIMIT 5.0A
- +
- +
DEC
INC
DEC
INC
Batt type
Start
'>3 seconds'
Stop
Enter
NIMH 2.0A 7.42V
CHG 022:45 00890
Battery
Elapsed
Battery
type
time
voltage
Charge current
Charged capacity
The value of discharge current on the left can not exceed 1C, and
the value on the right can not be under the voltage recommended
by the manufacturer to avoid deep discharging. Press
START/ENTER for more than 3 seconds to start discharging.
This shows the real-time status of discharging, you can press
BATT TYPE/STOP key to stop discharging.
The processor detects voltage of one cell is too low.
The 4th cell was damaged. The value of voltage may be zero if
disconnection occurs.
This program is for charging of NiCd/NiMH batteries associated
with R/C models applications. You can press START/ENTER key
to make it blink and then INC or DEC to change the parameter
value. Press START/ENTER key to store the value.
The screen shows the real-time status. Press BATT TYPE/STOP
key to end the program. The sound will emitted to indicates the
end of program.
DISCHARGING OF LITHIUM BATTERY

Advertisement

Table of Contents
loading

Table of Contents