Pb Lead-Acid Battery Program - Skyrc Ultimate Duo D260 Instruction Manual

Balance charger / discharger / power supply
Hide thumbs Also See for Ultimate Duo D260:
Table of Contents

Advertisement

Additional NiMH/NiCd Process Information:
During the NiMH/NiCd battery charging/discharging process the D260 can display a
variety of information. Using the INC or DEC buttons, you can also view the following
information:
NIMH SENSITIVITY
D.PEAK 4MV/CELL
Int. Temp 37 C
SAFETY TIMER
ON 200MIN

Pb Lead-Acid Battery Program

Pb (Lead-Acid):
BATT/PROGRAM
Pb BATT
Pb Charge Mode:
After selecting the correct battery type, use the INC or DEC button to change it to the
"NORMAL CHG" mode.
Press the START button and the amp rate value will begin flashing. Use the INC or DEC
buttons to adjust the value to the desired charge rate. The amp rate should be set to
1/10th of capacity. For example, if you are charging a 20Ah battery the charge rate should
be set to 2A. Follow the instructions provided on your battery when setting the amp rate.
D260
Pb Lead-Acid Battery Program
Delta peak voltage
Sensitivity setting
Internal temperature
Safety timer
setting
This program is only suitable for charging Pb(lead-acid)
batteries with nominal voltage ranging from 2 to 20V which are
significantly different from NiMH/NiCd batteries. Pb batteries are
suggested to charge with a low current of 0.1C and cannot be
used for fast charging. Please follow the instructions provided by
the battery manufacturer.
The D260 offers the following Pb charge modes: Charge and
Discharge.
IN POWER VOLTAGE
12.56V
CAPACITY CUT-OFF
ON 5000MAH
Input voltage
Capacity limit
setting
21 ·

Advertisement

Table of Contents
loading

Table of Contents