4. Operate the mode switch within one minute according to the messages to change the mode switch.
A login authentication timeout will occur after one minute.
Change the panel mode switch to Locked and press return...
Leave it in that position for at least 5 seconds.
Change the panel mode switch to Service, and press return...
5. Confirm that the XSCF Shell prompt is displayed on the administration console.
XSCF>
6. Initialize the XSCF settings. The following are the required settings for installation.
Settings
Registration of an XSCF user account, password, and user privileges
Registration of a user account of a field engineer (FE) (for maintenance)
Date and time settings
Confirmation of the XSCF host public key
SSH/telnet settings
Network interface, routing, and DNS-related settings
Domain-SP Communication Protocol (DSCP) settings
Altitude administration setting
Dual power feed option setting
* To apply the settings, the XSCF unit must be reset with the applynetwork and rebootxscf commands.
† To apply the settings, the XSCF unit must be reset with the rebootxscf commands.
‡ To apply changes made with the setdualpowerfeed command, power to the server must be completely disconnected and then
reconnected (all power cords must be disconnected and then reconnected). Wait at least 30 seconds before reconnecting the power cords to
the server.
For details on the setting procedure, see the SPARC Enterprise M3000/M4000/M5000/M8000/M9000 Servers
XSCF User's Guide.
7. Log in to the XSCF Shell with the user account and password that were set in

▼ Power On the Server

1. The following steps will power on the server.
a. Confirm that the mode switch on the operator panel is set to the Service mode (
b. From the XSCF Shell, enter the following console command:
XSCF> console -d 0
Connect to DomainID 0?[y|n] :y
This switches you from the XSCF Shell to the domain console.
c. Confirm that the XSCF STANDBY LED (
*
) on the operator panel is on.
Command
adduser, password,
setprivileges